Your browser doesn't support javascript.
loading
Effectiveness in Sterilization of Objects Produced by 3D Printing with Polylactic Acid Material: Comparison Between Autoclave and Ethylene Oxide Methods.
Ramos, Carlos Henrique; Wild, Pedro Minuzzi; Martins, Eduardo de Carvalho.
Afiliação
  • Ramos CH; Departamento de Ortopedia e Traumatologia do Hospital XV, Curitiba, PR, Brasil.
  • Wild PM; Departamento de Ortopedia e Traumatologia do Hospital XV, Curitiba, PR, Brasil.
  • Martins EC; Departamento de Ortopedia e Traumatologia do Hospital XV, Curitiba, PR, Brasil.
Rev Bras Ortop (Sao Paulo) ; 58(2): 284-289, 2023 Apr.
Article em En | MEDLINE | ID: mdl-37252310
Objective Due to the popularity of 3D technology, surgeons can create specific surgical guides and sterilize them in their institutions. The aim of the present study is to compare the efficacy of the autoclave and ethylene oxide (EO) sterilization methods for objects produced by 3D printing with polylactic acid (PLA) material. Methods Forty cubic-shaped objects were printed with PLA material. Twenty were solid and 20 were hollow (printed with little internal filling). Twenty objects (10 solid and 10 hollow) were sterilized in autoclave, forming Group 1. The others (10 solid and 10 hollow) were sterilized in EO, composing Group 2. After sterilization, they were stored and referred to culture. Hollow objects of both groups were broken during sowing, communicating the dead space with the culture medium. The results obtained were statistically analyzed (Fisher exact test and residue analysis). Results In group 1 (autoclave), there was bacterial growth in 50% of solid objects and in 30% of hollow objects. In group 2 (EO), growth occurred in 20% of hollow objects, with no bacterial growth in solid objects (100% of negative samples). The bacteria isolated in the positive cases was non-coagulase-producing Staphylococcus Gram positive. Conclusions Sterilization by both autoclave and EO was not effective for hollow printed objects. Solid objects sterilized by autoclave did not demonstrate 100% of negative samples and were not safe in the present assay. Complete absence of contamination occurred only with solid objects sterilized by EO, which is the combination recommended by the authors.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Bras Ortop (Sao Paulo) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Bras Ortop (Sao Paulo) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha