Your browser doesn't support javascript.
loading
Lower Extremity Physical Performance Tests for the Assessment of Athletes via Telehealth are Reliable.
Jales, Maycon Thomas Moises; Barbosa, Germanna de Medeiros; Gonçalves, Gustavo Viotto; Fonseca Fialho, Hilmaynne Renaly; Calixtre, Letícia Bojikian; Kamonseki, Danilo Harudy.
Afiliação
  • Jales MTM; Faculty of Health Sciences of Trairi, Universidade Federal do Rio Grande do Norte (UFRN), Santa Cruz, RN,Brazil.
  • Barbosa GM; Faculty of Health Sciences of Trairi, Universidade Federal do Rio Grande do Norte (UFRN), Santa Cruz, RN,Brazil.
  • Gonçalves GV; Postgraduate Program in Rehabilitation Sciences, Faculty of Health Sciences of Trairi, Universidade Federal do Rio Grande do Norte, Santa Cruz, RN,Brazil.
  • Fonseca Fialho HR; Department of Physical Therapy, Universidade Federal de São Carlos (UFSCar), São Carlos, SP,Brazil.
  • Calixtre LB; Faculty of Health Sciences of Trairi, Universidade Federal do Rio Grande do Norte (UFRN), Santa Cruz, RN,Brazil.
  • Kamonseki DH; Department of Physical Therapy, Universidade Federal de São Carlos (UFSCar), São Carlos, SP,Brazil.
J Sport Rehabil ; 32(5): 612-616, 2023 Jul 01.
Article em En | MEDLINE | ID: mdl-37146987
CONTEXT: Lower extremity physical performance tests (PPTs) have been widely used in sports rehabilitation and are commonly performed in person. However, some situations may disrupt the in-person health care delivery, such as social distancing due to the pandemic, traveling, and living in remote locations. Those situations may require adjustments in planning and applying measurement tests, and telehealth has become an alternative. Nevertheless, the reliability of lower extremity PPT tests via telehealth is still unknown. OBJECTIVES: To verify the test-retest reliability, SEM, and the minimum detectable change (MDC95) of PPTs via telehealth. METHODS: Fifty asymptomatic athletes completed 2 assessment sessions 7 to 14 days apart. The assessment via telehealth consisted of warm-up exercises followed by the single-, triple-, and side-hop tests, and the long jump test, in random order. Intraclass correlation coefficient, SEM, and MDC95 were calculated for each PPT. RESULTS: Single-hop test showed good to excellent reliability, with SEM and MDC95 ranging from 6.06 to 9.24 cm and 16.79 to 25.61 cm, respectively. The triple-hop test showed excellent reliability, with SEM and MDC95 ranging from 13.17 to 28.17 cm and 30.72 to 78.07 cm, respectively. Side-hop tests showed moderate reliability, with SEM and MDC95 ranging from 0.67 to 1.22 seconds and 2.00 to 3.39 seconds, respectively. The long jump test showed excellent reliability, with SEM and MDC95 ranging from 5.34 to 8.34 cm and 14.80 to 23.11 cm, respectively. CONCLUSION: The test-retest reliability of those PPTs via telehealth was acceptable. The SEM and MDC were provided to assist clinicians in interpreting those PPTs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Telemedicina / Desempenho Atlético Limite: Humans Idioma: En Revista: J Sport Rehabil Assunto da revista: MEDICINA ESPORTIVA / REABILITACAO Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Telemedicina / Desempenho Atlético Limite: Humans Idioma: En Revista: J Sport Rehabil Assunto da revista: MEDICINA ESPORTIVA / REABILITACAO Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos