Your browser doesn't support javascript.
loading
Carbon Black Integrated Polylactic Acid Electrodes Obtained by Fused Deposition Modeling: A Powerful Tool for Sensing of Sulfanilamide Residues in Honey Samples.
Rocha, Raquel G; de Faria, Lucas V; Silva, Vanessa F; Muñoz, Rodrigo A A; Richter, Eduardo M.
Afiliação
  • Rocha RG; Institute of Chemistry, Federal University of Uberlândia, Avenida João Naves de Avila, 2121, 38408-100 Uberlândia, Minas Gerais, Brazil.
  • de Faria LV; Institute of Chemistry, Federal University of Uberlândia, Avenida João Naves de Avila, 2121, 38408-100 Uberlândia, Minas Gerais, Brazil.
  • Silva VF; Institute of Chemistry, Federal University of Uberlândia, Avenida João Naves de Avila, 2121, 38408-100 Uberlândia, Minas Gerais, Brazil.
  • Muñoz RAA; Institute of Chemistry, Federal University of Uberlândia, Avenida João Naves de Avila, 2121, 38408-100 Uberlândia, Minas Gerais, Brazil.
  • Richter EM; National Institute of Science and Technology in Bioanalysis-INCTBio, 13083-970 Campinas, Sao Paulo, Brazil.
J Agric Food Chem ; 71(6): 3060-3067, 2023 Feb 15.
Article em En | MEDLINE | ID: mdl-36720110
Sulfanilamide (SFL) is used to prevent infections in honeybees. However, many regulatory agencies prohibit or establish maximum levels of SFL residues in honey samples. Hence, we developed a low-cost and portable electrochemical method for SFL detection using a disposable device produced through 3D printing technology. In the proposed approach, the working electrode was printed using a conductive filament based on carbon black and polylactic acid and it was associated with square wave voltammetry (SWV). Under optimized SWV parameters, linear concentration ranges (1-10 µmol L-1 and 12.5-35.0 µmol L-1), a detection limit of 0.26 µmol L-1 (0.05 mg L-1), and suitable RSD values (2.4% for inter-electrode; n = 3) were achieved. The developed method was selective in relation to other antibiotics applied in honey samples, requiring only dilution in the electrolyte. The recovery values (85-120%) obtained by SWV were statistically similar (95% confidence level) to those obtained by HPLC, attesting to the accuracy of the analysis and the absence of matrix interference.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fuligem / Mel Limite: Animals Idioma: En Revista: J Agric Food Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fuligem / Mel Limite: Animals Idioma: En Revista: J Agric Food Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos