Effects of changes in inspired oxygen fraction on urinary oxygen tension measurements.
Osawa, Eduardo A; Cutuli, Salvatore L; Yanase, Fumitaka; Iguchi, Naoya; Bitker, Laurent; Maciel, Alexandre T; Lankadeva, Yugeesh R; May, Clive N; Evans, Roger G; Eastwood, Glenn M; Bellomo, Rinaldo.
Afiliação
  • Osawa EA; Imed Group Research Department, Sao Paulo, Brazil.
  • Cutuli SL; Intensive Care Unit, Hospital Sao Camilo, Unidade Pompeia, Sao Paulo, Brazil.
  • Yanase F; Department of Intensive Care, Austin Hospital, Melbourne, VIC, 3084, Australia.
  • Iguchi N; Dipartimento di Scienze dell'Emergenza, Anestesiologiche e della Rianimazione, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
  • Bitker L; Università Cattolica del Sacro Cuore, Rome, Italy.
  • Maciel AT; Department of Intensive Care, Austin Hospital, Melbourne, VIC, 3084, Australia.
  • Lankadeva YR; Australian and New Zealand Intensive Care Research Centre, Monash University, Melbourne, Australia.
  • May CN; Department of Intensive Care, Austin Hospital, Melbourne, VIC, 3084, Australia.
  • Evans RG; Department of Anaesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka University, Suita, Japan.
  • Eastwood GM; Pre-Clinical Critical Care Unit, Florey Institute of Neuroscience and Mental Health, University of Melbourne, Melbourne, VIC, Australia.
  • Bellomo R; Service de Médecine Intensive - Réanimation, Hôpital de La Croix Rousse, Hospices Civils de Lyon, Lyon, France.
Intensive Care Med Exp ; 10(1): 52, 2022 Dec 12.
Article em En | MEDLINE | ID: mdl-36504004
BACKGROUND: Continuous measurement of urinary PO2 (PuO2) is being applied to indirectly monitor renal medullary PO2. However, when applied to critically ill patients with shock, its measurement may be affected by changes in FiO2 and PaO2 and potential associated O2 diffusion between urine and ureteric or bladder tissue. We aimed to investigate PuO2 measurements in septic shock patients with a fiberoptic luminescence optode inserted into the urinary catheter lumen in relation to episodes of FiO2 change. We also evaluated medullary and urinary oxygen tension values in Merino ewes at two different FiO2 levels. RESULTS: In 10 human patients, there were 32 FiO2 decreases and 31 increases in FiO2. Median pre-decrease FiO2 was 0.36 [0.30, 0.39] and median post-decrease FiO2 was 0.30 [0.23, 0.30], p = 0.006. PaO2 levels decreased from 83 mmHg [77, 94] to 72 [62, 80] mmHg, p = 0.009. However, PuO2 was 23.2 mmHg [20.5, 29.0] before and 24.2 mmHg [20.6, 26.3] after the intervention (p = 0.56). The median pre-increase FiO2 was 0.30 [0.21, 0.30] and median post-increase FiO2 was 0.35 [0.30, 0.40], p = 0.008. PaO2 levels increased from 64 mmHg [58, 72 mmHg] to 71 mmHg [70, 100], p = 0.04. However, PuO2 was 25.0 mmHg [IQR: 20.7, 26.8] before and 24.3 mmHg [IQR: 20.7, 26.3] after the intervention (p = 0.65). A mixed linear regression model showed a weak correlation between the variation in PaO2 and the variation in PuO2 values. In 9 Merino ewes, when comparing oxygen tension levels between FiO2 of 0.21 and 0.40, medullary values did not differ (25.1 ± 13.4 mmHg vs. 27.9 ± 15.4 mmHg, respectively, p = 0.6766) and this was similar to urinary oxygen values (27.1 ± 6.17 mmHg vs. 29.7 ± 4.41 mmHg, respectively, p = 0.3192). CONCLUSIONS: Changes in FiO2 and PaO2 within the context of usual care did not affect PuO2. Our findings were supported by experimental data and suggest that PuO2 can be used as biomarker of medullary oxygenation irrespective of FiO2.