Your browser doesn't support javascript.
loading
Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values.
Braambati, Dieimes; Monteiro Netto, Renata de Castro; Coelho, Marcelo Santos; Soares, Adriana de Jesus; Frozoni, Marcos.
Afiliação
  • Braambati D; Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil.
  • Monteiro Netto RC; Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil.
  • Coelho MS; Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil.
  • Soares AJ; Endodontic Department, State University of Campinas, Piracicaba- SP, Brazil.
  • Frozoni M; Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil.
Braz Dent J ; 33(6): 28-35, 2022.
Article em En | MEDLINE | ID: mdl-36477962
This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata País/Região como assunto: America do sul / Brasil Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata País/Região como assunto: America do sul / Brasil Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil