Development of a 3D disposable device for the electrochemical determination of diclofenac in different matrices.
Lisboa, Thalles Pedrosa; de Oliveira, Wallace Burger Veríssimo; de Souza, Cassiano Cunha; Oliveira, Raylla Santos; Matos, Maria Auxiliadora Costa; Matos, Renato Camargo.
Afiliação
  • Lisboa TP; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil. thallespl_jf@hotmail.com.
  • de Oliveira WBV; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil.
  • de Souza CC; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil.
  • Oliveira RS; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil.
  • Matos MAC; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil.
  • Matos RC; Departamento de Química, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36026-900, Brazil.
Anal Bioanal Chem ; 415(2): 357-366, 2023 Jan.
Article em En | MEDLINE | ID: mdl-36344667
In this work, the development of a disposable electrochemical device (US$ 0.02 per electrode) using a 3D printed support (3Ds) of acrylonitrile butadiene styrene (ABS) insulating filament with a composite material (CM) based on graphite and nail polish, immobilized on the support surface, was described for the electrochemical determination of diclofenac (DCF). The device was compared to the commercial glassy carbon electrode (GCE) and showed superior electroanalytical performance with approximately 1.8-fold higher current density. Additionally, an amperometric method for DCF determination in tap water, synthetic urine, and pharmaceutical formulation samples with the proposed electrode, using a flow injection analysis (FIA-AD) system, was developed. The optimized method presented excellent detectability (LOD = 0.47 µmol L-1), with excellent precision and accuracy (relative standard deviation < 5.6%) and percent recovery from spiked samples ranging from 89 to 106%. In addition, the sensor showed optimal analytical frequency with approximately 108 injections per hour, which demonstrates the potential of this system using the proposed disposable electrode for implementation in routine analysis and quality control with good selectivity and sensitivity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diclofenaco / Grafite Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha