Your browser doesn't support javascript.
loading
Local-Sensitive Connectivity Filter (LS-CF): A Post-Processing Unsupervised Improvement of the Frangi, Hessian and Vesselness Filters for Multimodal Vessel Segmentation.
Rodrigues, Erick O; Rodrigues, Lucas O; Machado, João H P; Casanova, Dalcimar; Teixeira, Marcelo; Oliva, Jeferson T; Bernardes, Giovani; Liatsis, Panos.
Afiliação
  • Rodrigues EO; Department of Academic Informatics (DAINF), Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco 85503-390, PR, Brazil.
  • Rodrigues LO; Graduate Program of Sciences Applied to Health Products, Universidade Federal Fluminense (UFF), Niteroi 24241-000, RJ, Brazil.
  • Machado JHP; Department of Academic Informatics (DAINF), Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco 85503-390, PR, Brazil.
  • Casanova D; Department of Academic Informatics (DAINF), Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco 85503-390, PR, Brazil.
  • Teixeira M; Department of Academic Informatics (DAINF), Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco 85503-390, PR, Brazil.
  • Oliva JT; Department of Academic Informatics (DAINF), Universidade Tecnologica Federal do Parana (UTFPR), Pato Branco 85503-390, PR, Brazil.
  • Bernardes G; Institute of Technological Sciences (ICT), Universidade Federal de Itajuba (UNIFEI), Itabira 35903-087, MG, Brazil.
  • Liatsis P; Department of Electrical Engineering and Computer Science, Khalifa University of Science and Technology, Abu Dhabi P.O. Box 127788, United Arab Emirates.
J Imaging ; 8(10)2022 Oct 21.
Article em En | MEDLINE | ID: mdl-36286385
A retinal vessel analysis is a procedure that can be used as an assessment of risks to the eye. This work proposes an unsupervised multimodal approach that improves the response of the Frangi filter, enabling automatic vessel segmentation. We propose a filter that computes pixel-level vessel continuity while introducing a local tolerance heuristic to fill in vessel discontinuities produced by the Frangi response. This proposal, called the local-sensitive connectivity filter (LS-CF), is compared against a naive connectivity filter to the baseline thresholded Frangi filter response and to the naive connectivity filter response in combination with the morphological closing and to the current approaches in the literature. The proposal was able to achieve competitive results in a variety of multimodal datasets. It was robust enough to outperform all the state-of-the-art approaches in the literature for the OSIRIX angiographic dataset in terms of accuracy and 4 out of 5 works in the case of the IOSTAR dataset while also outperforming several works in the case of the DRIVE and STARE datasets and 6 out of 10 in the CHASE-DB dataset. For the CHASE-DB, it also outperformed all the state-of-the-art unsupervised methods.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Imaging Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Imaging Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça