Your browser doesn't support javascript.
loading
A simple method to quantify azo dyes in spices based on flow injection chromatography combined with chemometric tools.
Nussbaum, Luana; Llamas, Natalia; Chocholous, Petr; Rodríguez, María Susana; Sklenárová, Hana; Solich, Petr; Di Anibal, Carolina; Acebal, Carolina C.
Afiliação
  • Nussbaum L; Departamento de Química, INQUISUR, Universidad Nacional del Sur (UNS)-CONICET, Av. Alem 1253, 8000 Bahía Blanca, Argentina.
  • Llamas N; Departamento de Química, INQUISUR, Universidad Nacional del Sur (UNS)-CONICET, Av. Alem 1253, 8000 Bahía Blanca, Argentina.
  • Chocholous P; Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, 500 05 Hradec Králové, Czechia.
  • Rodríguez MS; Departamento de Química, INQUISUR, Universidad Nacional del Sur (UNS)-CONICET, Av. Alem 1253, 8000 Bahía Blanca, Argentina.
  • Sklenárová H; Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, 500 05 Hradec Králové, Czechia.
  • Solich P; Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, 500 05 Hradec Králové, Czechia.
  • Di Anibal C; Departamento de Química, INQUISUR, Universidad Nacional del Sur (UNS)-CONICET, Av. Alem 1253, 8000 Bahía Blanca, Argentina.
  • Acebal CC; Departamento de Química, INQUISUR, Universidad Nacional del Sur (UNS)-CONICET, Av. Alem 1253, 8000 Bahía Blanca, Argentina.
J Food Sci Technol ; 59(7): 2764-2775, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35734112
Para Red (PR) and Sudan dyes have been illegally used as colorants to adulterate certain foods by enhancing their red/orange colour. In addition, they are toxic and carcinogenic. This work presents the development of a simple flow injection chromatographic method combined with chemometric tools to perform the determination of PR, Sudan I (SI) and Sudan II (SII) in food samples. The flow chromatographic system consisted of a low-pressure manifold coupled to a reverse phase monolithic column. A Partial Least Square (PLS) model was applied to resolve overlapped absorption spectra registered for each dye at the corresponding retention time. The relative errors of calibration (RMSECV, %) were 0.49, 0.85 and 0.23, and the relative errors of prediction (RMSEP, %) were 1.12, 0.75 and 0.33 for PR, SI and SII, respectively. The residual predictive deviation (RPD) values obtained were higher than 3.00 for all analytes. The method was successfully applied to quantify the dyes in six different commercial spices samples. The results were compared with the HPLC reference method concluding that there were no significant differences at the studied confidence level (α = 0.05). The proposed method can be used to rapidly determine the analytes in a simple, reliable, low-cost and environmentally-friendly manner. Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-021-05299-8.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Food Sci Technol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Argentina País de publicação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Food Sci Technol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Argentina País de publicação: Índia