Your browser doesn't support javascript.
loading
Experimental determination of k0 and Q0 values for 121Sb, 123Sb and 130Ba targets applying covariance analysis.
Barros, L F; Dias, M S; Koskinas, M F.
Afiliação
  • Barros LF; Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Centro do Reator de Pesquisas - CRPq, C.P. 11049, Pinheiros, 05422-970, São Paulo, SP, Brazil. Electronic address: lfbarros@ipen.br.
  • Dias MS; Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Centro do Reator de Pesquisas - CRPq, C.P. 11049, Pinheiros, 05422-970, São Paulo, SP, Brazil.
  • Koskinas MF; Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Centro do Reator de Pesquisas - CRPq, C.P. 11049, Pinheiros, 05422-970, São Paulo, SP, Brazil.
Appl Radiat Isot ; 184: 110122, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35272231
This work consists of an experimental determination of k0 and Q0 for 121Sb, 123Sb and 130Ba targets. Covariance analysis has been introduced to supply not only the overall uncertainties in these parameters but also their correlations. The irradiations were performed near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Nuclear and Energy Research Institute (IPEN-CNEN/SP), in São Paulo, Brazil. The epithermal neutron flux shape parameter, alpha, at the irradiation position is very close to zero, which favors to obtain Q0 values more accurately. Two irradiations were carried out in sequence, using two sets of samples: the first with bare samples and the second inside a Cd cover. The activity measurements were carried out in a previously calibrated HPGe gamma-ray spectrometer. The measurements were corrected for: saturation, decay time, cascade summing, geometry, self-attenuation, measuring time and mass. Standard sources of 152Eu, 133Ba, 60Co and 137Cs traceable to a 4πß-γ primary system were used to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The experimental efficiency curve was performed by a fourth-degree polynomial fit, in the energy range of the standard sources, 121-1408 keV, it contains all correlations between points. For energies above 1408 keV, the efficiencies were obtained by the Monte Carlo Method. The covariance matrix methodology was applied to all uncertainties involved. The final values for k0 and Q0 were compared with the literature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Método de Monte Carlo Tipo de estudo: Health_economic_evaluation País/Região como assunto: America do sul / Brasil Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2022 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Método de Monte Carlo Tipo de estudo: Health_economic_evaluation País/Região como assunto: America do sul / Brasil Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2022 Tipo de documento: Article País de publicação: Reino Unido