Comparison Between Pressure Swing Adsorption and Liquid Oxygen Enrichment Techniques in the Atacama Large Millimeter/Submillimeter Array Facility at the Chajnantor Plateau (5,050 m).
Lopez, Ivan; Aravena, Reinaldo; Soza, Daniel; Morales, Alicia; Riquelme, Silvia; Calderon-Jofré, Rodrigo; Moraga, Fernando A.
Afiliação
  • Lopez I; Atacama Large Millimeter/Submillimeter Array, San Pedro de Atacama, Chile.
  • Aravena R; Atacama Large Millimeter/Submillimeter Array, San Pedro de Atacama, Chile.
  • Soza D; Atacama Large Millimeter/Submillimeter Array, San Pedro de Atacama, Chile.
  • Morales A; Atacama Large Millimeter/Submillimeter Array, San Pedro de Atacama, Chile.
  • Riquelme S; Departamento de Medicina, Facultad de Ciencias de la Salud, Universidad de Tarapacá, Arica, Chile.
  • Calderon-Jofré R; Laboratorio de Fisiología, Hipoxia y Función Vascular, Departamento de Ciencias Biomédicas, Facultad de Medicina, Universidad Católica del Norte, Coquimbo, Chile.
  • Moraga FA; Laboratorio de Fisiología, Hipoxia y Función Vascular, Departamento de Ciencias Biomédicas, Facultad de Medicina, Universidad Católica del Norte, Coquimbo, Chile.
Front Physiol ; 12: 775240, 2021.
Article em En | MEDLINE | ID: mdl-34955888
The Chilean workforce has over 200,000 people that are intermittently exposed to altitudes over 4,000 m. In 2012, the Ministry of Health provided a technical guide for high-altitude workers that included a series of actions to mitigate the effects of hypoxia. Previous studies have shown the positive effect of oxygen enrichment at high altitudes. The Atacama Large Millimeter/submillimeter Array (ALMA) radiotelescope operates at 5,050 m [Array Operations Site (AOS)] and is the only place in the world where pressure swing adsorption (PSA) and liquid oxygen technologies have been installed at a large scale. These technologies reduce the equivalent altitude by increasing oxygen availability. This study aims to perform a retrospective comparison between the use of both technologies during operation in ALMA at 5,050 m. In each condition, variables such as oxygen (O2), temperature, and humidity were continuously recorded in each AOS rooms, and cardiorespiratory variables were registered. In addition, we compared portable O2 by using continuous or demand flow during outdoor activities at very high altitudes. The outcomes showed no differences between production procedures (PSA or liquid oxygen) in regulating oxygen availability at AOS facilities. As a result, big-scale installations have difficulties reaching the appropriate O2 concentration due to leaks in high mobility areas. In addition, the PSA plant requires adequacy and maintenance to operate at a very high altitude. A continuous flow of 2-3 l/min of portable O2 is recommended at 5,050 m.