Your browser doesn't support javascript.
loading
Assessment of short-term intraocular pressure parameters in phakic and pseudophakic patients with primary open-angle glaucoma.
Lourenço, Adriana Sobral; Araújo, Candice Cristina Quirino de; Santos, Procópio Miguel Dos; Prata, Tiago S; Lopes, Nara Lidia Vieira; Santos, Regina Cândido Ribeiro Dos; Gracitelli, Carolina P B; Faria, Nubia Vanessa Lima de.
Afiliação
  • Lourenço AS; Department of Ophthalmology, Hospital das Forças Armadas, Brasília, DF, Brazil.
  • Araújo CCQ; Department of Ophthalmology, Universidade Federal de Brasilia, Brasília, DF, Brazil.
  • Santos PMD; Department of Ophthalmology, Universidade Federal de Brasilia, Brasília, DF, Brazil.
  • Prata TS; Department of Ophthalmology and Visual Science, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Lopes NLV; Ophthalmology, Mayo Clinic, Jacksonville, United States.
  • Santos RCRD; Ophthalmology, Hospital Medicina dos Olhos, Osasco, SP, Brazil.
  • Gracitelli CPB; Department of Ophthalmology and Visual Science, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Faria NVL; Centro Brasileiro da Visão, Brasilia, DF, Brazil.
Arq Bras Oftalmol ; 84(5): 425-429, 2021.
Article em En | MEDLINE | ID: mdl-34320100
PURPOSE: To investigate intraocular pressure peaks in phakic and pseudophakic patients with primary open-angle glaucoma. METHOD: Overall, 40 patients with primary open-angle glaucoma were assessed. Of these, 20 patients were phakic and 20 pseudophakic. One eye (randomly selected) was included in the study. All patients underwent the intraocular pressure curves test, followed by the water-drinking test. RESULTS: A statistically significant difference was observed between the phakic and pseudophakic patients regarding the mean of the peaks in the intraocular pressure curves (p=0.045). A statistically significant intergroup difference was noted regarding the intraocular pressure peaks in the water-drinking test, with higher values observed in the phakic patients (p 0.004). CONCLUSION: The intraocular pressure peaks in the water-drinking test and intraocular pressure curves were higher in the phakic group than in the pseudophakic group.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil