Your browser doesn't support javascript.
loading
A fast and direct determination of bisphenol S in thermal paper samples using paper spray ionization mass spectrometry.
Bernardo, Ricardo Alves; Sousa, Jean Carlos Pereira; Gallimberti, Matheus; Junior, Fernando Barbosa; Vaz, Boniek Gontijo; Chaves, Andréa Rodrigues.
Afiliação
  • Bernardo RA; Institute of Chemistry, Federal University of Goiás, Goiânia, GO, 74690-900, Brazil.
  • Sousa JCP; Institute of Chemistry, Federal University of Goiás, Goiânia, GO, 74690-900, Brazil.
  • Gallimberti M; Faculty of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-900, Brazil.
  • Junior FB; Faculty of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-900, Brazil.
  • Vaz BG; Institute of Chemistry, Federal University of Goiás, Goiânia, GO, 74690-900, Brazil.
  • Chaves AR; Institute of Chemistry, Federal University of Goiás, Goiânia, GO, 74690-900, Brazil. andrea_chaves@ufg.br.
Environ Sci Pollut Res Int ; 28(40): 57288-57296, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34089157
Concerns about human health regarding the large use of bisphenol A in thermal papers have led to its replacement by bisphenol S. Analyses of bisphenols require several sample pretreatment steps, which are laborious, expensive, and time-consuming. A paper spray ionization mass spectrometry (PSI-MS) was developed to detect and quantify bisphenol S in three different brands of thermal papers commercially available. Parameters such as paper size, and paper position relative to the mass spectrometer inlet were evaluated. The analyses were performed in selected ion monitoring mode on a linear ion trap mass spectrometer. The developed method presented absolute recovery values ranging from 92.2 to 109.04%, accuracy values from -1.2 to 9.0%, and inter assay precision from 1.8 to 5.6% and enabled LOD as low as 5 ng g-1. The concentration of bisphenol S in all of the three brands of BPA-free thermal papers evaluated ranged from 1.36 to 6.77 µg g-1, and the concentrarion of BPA ranged from 6.56 to 16.4 µg g-1 in all samples of thermal paper evaluated. The PSI-MS method described here was comparable to the conventional ones, such as liquid chromatography coupled with mass spectrometry and gas chromatography coupled with mass spectrometry described in the literature. The present study proved to be practical, fast, and efficient for the direct determination of bisphenol S in thermal papers. Furthermore, the methodology here described showed to be a promising alternative to replace the classical methods for determination of bisphenol S, due to its simplicity, and no needing of any sample pretreatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha