Your browser doesn't support javascript.
loading
A comparative study of photo-Fenton process assisted by natural sunlight, UV-A, or visible LED light irradiation for degradation of real textile wastewater: factorial designs, kinetics, cost assessment, and phytotoxicity studies.
de Souza, Ziani S B; Silva, Maryne P; Fraga, Tiago J M; Motta Sobrinho, Maurício A.
Afiliação
  • de Souza ZSB; Department of Chemical Engineering, Federal University of Pernambuco (UFPE), 1235 Prof. Moraes Rego Avenue, Cidade Universitária, Recife, Pernambuco, 50670-901, Brazil. zianisbs@gmail.com.
  • Silva MP; Department of Chemical Engineering, Federal University of Pernambuco (UFPE), 1235 Prof. Moraes Rego Avenue, Cidade Universitária, Recife, Pernambuco, 50670-901, Brazil.
  • Fraga TJM; Department of Chemical Engineering, Federal University of Pernambuco (UFPE), 1235 Prof. Moraes Rego Avenue, Cidade Universitária, Recife, Pernambuco, 50670-901, Brazil.
  • Motta Sobrinho MA; Department of Chemical Engineering, Federal University of Pernambuco (UFPE), 1235 Prof. Moraes Rego Avenue, Cidade Universitária, Recife, Pernambuco, 50670-901, Brazil.
Environ Sci Pollut Res Int ; 28(19): 23912-23928, 2021 May.
Article em En | MEDLINE | ID: mdl-33394423
The present work aims to evaluate the treatment of the effluent from the textile industry via advanced oxidative processes of photo-Fenton assisted by different sources (natural sunlight, UV-A or visible LED lamps). To identify the best operating conditions, a factorial design was carried out for each process. It was observed that after the optimization of the processes, chemical oxygen demand (COD) removals greater than 88% were achieved. In addition, it was observed that the use of the LED lamp required lower reagent concentrations compared to solar and UV-A sources. A kinetic study was carried out under the best conditions obtained and it was observed that the sources showed rapid evolution, reaching a COD removal equilibrium with 30 min of reaction. Reagent monitoring was also carried out, and it was observed that they were not limiting to the reaction. Phytotoxicity analysis was also satisfactory since the treated effluents allowed a higher relative growth and germination index of the cucumber roots compared to the raw effluent. Finally, the cost analysis indicated that the use of LED lamps resulted in a reduction in electrical consumption compared to the UV-A lamp, as well as a reduction in the cost of reagents due to the lower concentration of reagents required compared to processes assisted by natural sunlight and UV-A.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Águas Residuárias Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Águas Residuárias Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha