Your browser doesn't support javascript.
loading
Removal of Cu(II) by Fixed-Bed Columns Using Alg-Ch and Alg-ChS Hydrogel Beads: Effect of Operating Conditions on the Mass Transfer Zone.
Verduzco-Navarro, Ilse Paulina; Rios-Donato, Nely; Jasso-Gastinel, Carlos Federico; Martínez-Gómez, Álvaro de Jesús; Mendizábal, Eduardo.
Afiliação
  • Verduzco-Navarro IP; Chemistry Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara, Jalisco 44430, Mexico.
  • Rios-Donato N; Chemistry Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara, Jalisco 44430, Mexico.
  • Jasso-Gastinel CF; Chemical Engineering Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara, Jalisco 44430, Mexico.
  • Martínez-Gómez ÁJ; Chemical Engineering Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara, Jalisco 44430, Mexico.
  • Mendizábal E; Chemistry Department, CUCEI, University of Guadalajara, Blvd. Gral. Marcelino García Barragán 1421, Guadalajara, Jalisco 44430, Mexico.
Polymers (Basel) ; 12(10)2020 Oct 13.
Article em En | MEDLINE | ID: mdl-33066244
The removal of Cu(II) ions from aqueous solutions at a pH of 5.0 was carried out using fixed-bed columns packed with alginate-chitosan (Alg-Ch) or alginate-chitosan sulfate (Alg-ChS) hydrogel beads. The effect of the initial Cu(II) concentration, flow rate, pH, and height of the column on the amount of Cu removed by the column at the breakpoint and at the exhaustion point is reported. The pH of the solution at the column's exit was initially higher than that at the entrance, and then decreased slowly. This pH increase was attributed to proton transfer from the aqueous solution to the amino and COO- groups of the hydrogel. The effect of operating conditions on the mass transfer zone (MTZ) and the length of the unused bed (HLUB) is reported. At the lower flow rate and lower Cu(II) concentration used, the MTZ was completely developed and the column operated efficiently; by increasing column height, the MTZ has a better opportunity to develop fully. Experimental data were fitted to the fixed-bed Thomas model using a non-linear regression analysis and a good correspondence between experimental and Thomas model curves was observed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: México País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: México País de publicação: Suíça