A carbon paste electrode improved with poly(ethylene glycol) for tannic acid surveillance in beer samples.
Piovesan, Jamille V; Santana, Edson R; Spinelli, Almir.
Afiliação
  • Piovesan JV; Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Departamento de Química - CFM, 88040-900 Florianópolis, SC, Brazil.
  • Santana ER; Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Departamento de Química - CFM, 88040-900 Florianópolis, SC, Brazil.
  • Spinelli A; Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Departamento de Química - CFM, 88040-900 Florianópolis, SC, Brazil. Electronic address: almir.spinelli@ufsc.br.
Food Chem ; 326: 127055, 2020 Oct 01.
Article em En | MEDLINE | ID: mdl-32438225
Tannic acid is often used as additive in beers and is an important parameter to be evaluated in quality control of beverages. Thus, this paper describes the improvement of a carbon paste electrode through its modification with poly(ethylene glycol) for determination of tannic acid in beers. Microscopic and electrochemical techniques were used to characterize the modified surface. The electrochemical behavior of tannic acid and the optimization of experimental parameters (pH, supporting electrolyte and accumulation step) on the modified surface were performed by cyclic voltammetry. The calibration plot for tannic acid by differential pulse voltammetry was linear in the range of 0.08-2.10 µmol L-1 with limits of detection and quantification of 72.6 and 220 nmol L-1, respectively. Lastly, the carbon paste electrode improved with poly(ethylene glycol) was effectively implemented in the quantification of tannic acid in beer samples. The results were similar to those furnished by the Folin-Ciocalteu method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Taninos / Cerveja / Carbono Tipo de estudo: Screening_studies Idioma: En Revista: Food Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Taninos / Cerveja / Carbono Tipo de estudo: Screening_studies Idioma: En Revista: Food Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido