Your browser doesn't support javascript.
loading
Survival Probability, Weibull Characteristics, Stress Distribution, and Fractographic Analysis of Polymer-Infiltrated Ceramic Network Restorations Cemented on a Chairside Titanium Base: An In Vitro and In Silico Study.
Tribst, João P M; Dal Piva, Amanda M O; Borges, Alexandre L S; Anami, Lilian C; Kleverlaan, Cornelis J; Bottino, Marco A.
Afiliação
  • Tribst JPM; Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Institute of Science and Technology, 12245-000 São José dos Campos, Brazil.
  • Dal Piva AMO; Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Institute of Science and Technology, 12245-000 São José dos Campos, Brazil.
  • Borges ALS; Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Institute of Science and Technology, 12245-000 São José dos Campos, Brazil.
  • Anami LC; Department of Dentistry, Santo Amaro University (UNISA), 04743-030 São Paulo, Brazil.
  • Kleverlaan CJ; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands.
  • Bottino MA; Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Institute of Science and Technology, 12245-000 São José dos Campos, Brazil.
Materials (Basel) ; 13(8)2020 Apr 16.
Article em En | MEDLINE | ID: mdl-32316360
Different techniques are available to manufacture polymer-infiltrated ceramic restorations cemented on a chairside titanium base. To compare the influence of these techniques in the mechanical response, 75 implant-supported crowns were divided in three groups: CME (crown cemented on a mesostructure), a two-piece prosthetic solution consisting of a crown and hybrid abutment; MC (monolithic crown), a one-piece prosthetic solution consisting of a crown; and MP (monolithic crown with perforation), a one-piece prosthetic solution consisting of a crown with a screw access hole. All specimens were stepwise fatigued (50 N in each 20,000 cycles until 1200 N and 350,000 cycles). The failed crowns were inspected under scanning electron microscopy. The finite element method was applied to analyze mechanical behavior under 300 N axial load. Log-Rank (p = 0.17) and Wilcoxon (p = 0.11) tests revealed similar survival probability at 300 and 900 N. Higher stress concentration was observed in the crowns' emergence profiles. The MP and CME techniques showed similar survival and can be applied to manufacture an implant-supported crown. In all groups, the stress concentration associated with fractographic analysis suggests that the region of the emergence profile should always be evaluated due to the high prevalence of failures in this area.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Revista: Materials (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Revista: Materials (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça