Your browser doesn't support javascript.
loading
A Facile Preparation of a New Water-Soluble Acridine Derivative and Application as a Turn-off Fluorescence Chemosensor for Selective Detection of Hg2.
Nunes, Marcelo Carpes; Dos Santos Carlos, Fabiane; Fuganti, Otávio; da Silva, Letícia Aparecida; Ribas, Hennrique Taborda; Winnischofer, Sheila Maria Brochado; Nunes, Fábio Souza.
Afiliação
  • Nunes MC; Departamento de Química, Universidade Federal do Paraná, Cx. Postal 19081, Curitiba, PR, 81531-980, Brazil.
  • Dos Santos Carlos F; Departamento de Química, Universidade Federal do Paraná, Cx. Postal 19081, Curitiba, PR, 81531-980, Brazil.
  • Fuganti O; Departamento de Química, Universidade Federal do Paraná, Cx. Postal 19081, Curitiba, PR, 81531-980, Brazil.
  • da Silva LA; Departamento de Química, Universidade Federal do Paraná, Cx. Postal 19081, Curitiba, PR, 81531-980, Brazil.
  • Ribas HT; Departamento de Bioquímica e Biologia Molecular, Universidade Federal do Paraná, Cx. Postal 19031, Curitiba, PR, 81531-980, Brazil.
  • Winnischofer SMB; Departamento de Bioquímica e Biologia Molecular, Universidade Federal do Paraná, Cx. Postal 19031, Curitiba, PR, 81531-980, Brazil.
  • Nunes FS; Departamento de Química, Universidade Federal do Paraná, Cx. Postal 19081, Curitiba, PR, 81531-980, Brazil. fsnunes@ufpr.br.
J Fluoresc ; 30(2): 235-247, 2020 Mar.
Article em En | MEDLINE | ID: mdl-31974874
A new acridine-based chemosensor was prepared, characterized and investigated for quantitative detection of Hg2+ ions in aqueous solutions. DFT and TD-DFT calculations showed that formation of a coordination bond between Hg2+ and the thiolate-sensor accounts for the fluorescence quenching, forming [HgLSCl2]2- as the most stable species. Limit of detection and limit of quantification were as low as 4.40 and 14.7 µmol L-1, respectively (R2 = 0.9892, least squares method), and a linear concentration range of 14.7-100 µmol L-1. Benesi-Hildebrand and Job formalisms are in accordance with the formation of a stable complex with a 1:1 (metal ion/sensor) ratio, and a determined binding constant of 5.14 × 103 L mol-1. Robustness was verified based on the variation of several analytical conditions. In addition, the method presented maximum relative standard deviation of 4.6%, and recovery results was (90.3 ± 4,6)% from distilled water, with no effect of interfering ions. Analytical figures of merit showed that the sensor can be an attractive low cost alternative for detection of Hg2+.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acridinas / Corantes Fluorescentes / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acridinas / Corantes Fluorescentes / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda