Your browser doesn't support javascript.
loading
Non-locked and locked small fragment straight plates have a similar behavior in buttressing the posteromedial shear tibial plateau fragment: a biomechanical analysis of three different fixations.
Giordano, Vincenzo; Kfuri, Mauricio; Belangero, William; Venturini, Allison; Silva, Ana Carolina; Soares, Eduardo Merjan; Pires, Robinson Esteves; Koch, Hilton A.
Afiliação
  • Giordano V; Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, RJ, Brazil. v_giordano@me.com.
  • Kfuri M; Clínica São Vicente, Rede D'or São Luiz, Rua Mário Ribeiro 117/2° andar, Leblon, Rio de Janeiro, RJ, 22430-160, Brazil. v_giordano@me.com.
  • Belangero W; Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA.
  • Venturini A; Departamento de Biomecânica, Medicina e Reabilitação do Sistema Locomotor, Escola de Medicina de Ribeirão Preto, Universidade de São Paulo (USP), Ribeirão Preto, SP, Brazil.
  • Silva AC; Laboratório de Biomateriais em Ortopedia, Faculdade de Ciências Médicas, Universidade de Campinas (UNICAMP), Campinas, SP, Brazil.
  • Soares EM; Departamento de Ortopedia, Faculdade de Ciências Médicas, Universidade de Campinas (UNICAMP), Campinas, SP, Brazil.
  • Pires RE; Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, RJ, Brazil.
  • Koch HA; Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, RJ, Brazil.
J Exp Orthop ; 7(1): 2, 2020 Jan 17.
Article em En | MEDLINE | ID: mdl-31953619
PURPOSE: The aim of this study is to compare the biomechanical behavior of three different fixation constructions currently used for buttressing the posteromedial shearing tibial plateau fragment. Our hypothesis is that non-locked implants provide sufficient comparable stability in posteromedial tibial plateau fractures as locked implants. METHODS: Fifteen left synthetic tibiae from a single manufacturing batch were used to create a posteromedial shear tibial plateau fracture. The fracture was buttressed with three different posteriorly placed five-hole straight small-fragment plate. Five models were fixed with a one-third tubular plate (TTP), five models with a dynamic compression plate (DCP), and five models with a locking compression plate (LCP). All groups were tested to vertical subsidence (Stage 1). In the same experiment (Stage 2), TTP and DCP groups were tested until catastrophic failure. Force versus displacement curves were obtained in the two stages of the experiment. RESULTS: Stage 1 - There was no significant difference in stiffness (p = 0.89), subsidence up to 2 mm (p = 0.38), and energy (p = 0.36) among the three fixation constructions. Stage 2 - Yield load revealed significantly less yield strength for the TTP group as compared with the DCP group (p = 0.048). However, there was no significant difference in maximum load to failure among the TTP and DCP fixation constructions (p = 0.16). CONCLUSION: Placement of either a locked or non-locked small fragment straight plate to buttress the posteromedial shear tibial plateau fragment has a similar biomechanical behavior. When the implant is positioned to buttress the shearing fragment it maximizes biomechanical stiffness.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Exp Orthop Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Exp Orthop Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha