Your browser doesn't support javascript.
loading
Glycated albumin as a diagnostic tool in diabetes: An alternative or an additional test?
Chume, Fernando Chimela; Kieling, Mayana Hernandez; Correa Freitas, Priscila Aparecida; Cavagnolli, Gabriela; Camargo, Joíza Lins.
Afiliação
  • Chume FC; Graduate Program in Medical Sciences: Endocrinology, Universidade Federal do Rio Grande do Sul Porto Alegre, Porto Alegre-RS, Brazil.
  • Kieling MH; Universidade Zambeze, Beira, Mozambique.
  • Correa Freitas PA; Graduate Program in Medical Sciences: Endocrinology, Universidade Federal do Rio Grande do Sul Porto Alegre, Porto Alegre-RS, Brazil.
  • Cavagnolli G; Graduate Program in Medical Sciences: Endocrinology, Universidade Federal do Rio Grande do Sul Porto Alegre, Porto Alegre-RS, Brazil.
  • Camargo JL; Laboratory Diagnosis Division, Clinical Biochemistry Unit, Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre-RS, Brazil.
PLoS One ; 14(12): e0227065, 2019.
Article em En | MEDLINE | ID: mdl-31891628
INTRODUCTION: Studies have revealed that glycated albumin (GA) is a useful alternative to HbA1c under conditions wherein the latter does not reflect glycaemic status accurately. Until now, there are few studies with non-Asians subjects that report on the validity of GA test in diagnosis of type 2 diabetes mellitus (DM). Thus, the aim of this study was to assess the clinical utility of GA in diagnosis of DM. MATERIALS AND METHODS: This diagnostic test accuracy study was performed in 242 Brazilian individuals referred for OGTT in a tertiary university hospital. ROC curves were used to access the performance of GA and HbA1c in the diagnosis of DM by oral glucose tolerance test (OGTT). RESULTS: OGTT, HbA1c and GA were performed in all 242 participants (40.5% male, age 54.4 ± 13.0 years [mean ± SD], body mass index 28.9 ± 6.3 kg/m2). DM by OGTT was detected in 31.8% of individuals. The equilibrium threshold value of GA ≥14.8% showed sensitivity of 64.9% and specificity of 65.5% for the diagnosis of DM. The AUC for GA [0.703 (95% CI 0.631-0.775)] was lower than for HbA1c [0.802 (95% CI 0.740-0.864)], p = 0.028. A GA value of 16.8% had similar accuracy for detecting DM as defined by HbA1c ≥6.5% (48 mmol/mol) with sensitivity of 31.2% and specificity of 93.3% for both tests. However, GA detects different subjects from those detected by HbA1c and OGTT. CONCLUSIONS: GA detected different individuals with DM from those detected by HbA1c, though it showed overall diagnostic accuracy similar to HbA1c in the diagnosis of DM. Therefore, GA should be used as an additional test rather than an alternative to HbA1c or OGTT and its use as the sole DM diagnostic test should be interpreted with caution.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Albumina Sérica / Diabetes Mellitus Tipo 2 Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Albumina Sérica / Diabetes Mellitus Tipo 2 Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos