Your browser doesn't support javascript.
loading
Using T1 as a direct detection dimension in two-dimensional time-domain NMR experiments using CWFP regime.
Monaretto, Tatiana; Montrazi, Elton Tadeu; Moraes, Tiago Bueno; Souza, Andre Alves; Rondeau-Mouro, Corinne; Colnago, Luiz Alberto.
Afiliação
  • Monaretto T; Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense 400, São Carlos, SP 13566-590, Brazil.
  • Montrazi ET; Instituto de Física de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense 400, São Carlos, SP 13566-590, Brazil.
  • Moraes TB; Instituto de Física de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense 400, São Carlos, SP 13566-590, Brazil.
  • Souza AA; Schlumberger Brazil Technology Integration Center, Av. Rep. do Chile, 330, Torre Oeste, 18° andar, Rio de Janeiro, RJ 20031-170, Brazil.
  • Rondeau-Mouro C; INRAE, UR OPAALE, 17 Avenue de Cucillé, CS 64427, 35044 Rennes Cedex, France.
  • Colnago LA; Embrapa Instrumentação, Rua XV de Novembro 1452, São Carlos, SP 13560-970, Brazil. Electronic address: luiz.colnago@embrapa.br.
J Magn Reson ; 311: 106666, 2020 02.
Article em En | MEDLINE | ID: mdl-31846810
The transverse relaxation time (T2), measured with Carr-Purcell-Meiboom-Gill (CPMG) sequence, has been widely used to obtain the direct dimension data in two-dimension time domain NMR (2D TD-NMR). In this paper we are demonstrating that Continuous Wave Free Precession sequence, with low flip angle (CWFP-T1), can be an alternative to CPMG as direct detection dimension. CWFP-T1 is a fast single shot sequence, like CPMG, and yields an exponential signal governed predominantly by the longitudinal (T1) relaxation time. To obtain the correlations between T1 and T2 (T1-T2 maps) we are proposing the use of CPMG-CWFP-T1 pulse sequence. In this sequence CPMG encodes T2 information (indirect dimension) that modulates the CWFP-T1 (direct dimension) signal amplitudes. CPMG-CWFP-T1 experiments were compared with classical 2D sequences such as Saturation-Recovery-CPMG (SR-CPMG) and Inversion-Recovery-CPMG (IR-CPMG) sequence and yields similar results in phantom sample. The experimental time for the 2D sequences, using single scan, shows that SR-CPMG ≤ CPMG-CWFP-T1 < IR-CPMG. Experimental and simulated results demonstrated that 2D-CPMG-CWFP-T1 maps have higher resolution in T1 dimension than the techniques that uses CPMG as direct dimension. CPMG-CWFP-T1 sequence was also applied to study beef samples, and 2D maps showed higher resolution in the two fat signals than the classical IR-CPMG method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética / Análise de Alimentos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Magn Reson Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética / Análise de Alimentos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Magn Reson Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos