Your browser doesn't support javascript.
loading
Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review.
Goiato, Marcelo Coelho; Andreotti, Agda Marobo; Dos Santos, Daniela Micheline; Nobrega, Adhara Smith; de Caxias, Fernanda Pereira; Bannwart, Lisiane Cristina.
Afiliação
  • Goiato MC; Professor, Department of Dental Materials and Prosthodontics; Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho, UNESP, Araçatuba, Brazil.
  • Andreotti AM; PhD Student; Department of Dental Materials and Prosthodontics; Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho, UNESP, Araçatuba, Brazi.
  • Dos Santos DM; Professor, Department of Dental Materials and Prosthodontics, Manaus, UNIP, Brazil.
  • Nobrega AS; PhD Student; Department of Dental Materials and Prosthodontics; Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho, UNESP, Araçatuba, Brazi.
  • de Caxias FP; PhD Student; Department of Dental Materials and Prosthodontics; Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho, UNESP, Araçatuba, Brazi.
  • Bannwart LC; Professor, Department of Dental Materials and Prosthodontics, Manaus, UNIP, Brazil.
Article em En | MEDLINE | ID: mdl-31592306
Background. Implant fractures can cause difficult problems for patients and dentists. This systematic review aimed to determine the influence of some implant parameters on the occurrence of their fracture and to determine the incidence of fractures reported in recent years. Methods. A search was conducted in Pubmed database, from which 12 studies published in the last 12 years were selected. Results. This review reported a 2% incidence of implant fracture. Most implants had been in function between 3 and 4 years until fracture. The studies did not provide necessary information to establish a relationship between the different parameters of implants and the incidence of fractures. Conclusion. Thus, the indication of type, diameter and length of an implant and the bone quality in the region receiving it should be studied and accurately examined for each individual case in order to avoid future failures.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Incidence_studies / Risk_factors_studies / Systematic_reviews Idioma: En Revista: J Dent Res Dent Clin Dent Prospects Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Incidence_studies / Risk_factors_studies / Systematic_reviews Idioma: En Revista: J Dent Res Dent Clin Dent Prospects Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Irã