Your browser doesn't support javascript.
loading
Relationship between Radiographic Misfit and Clinical Outcomes in Immediately Loaded Complete-Arch Fixed Implant-Supported Prostheses in Edentulous Patients.
Slauch, Robert W; Bidra, Avinash S; Wolfinger, Glenn J; Kuo, Chia-Ling.
Afiliação
  • Slauch RW; Pi Dental Center at the Institute for Facial Esthetics, Fort Washington, PA.
  • Bidra AS; Department of Reconstructive Sciences, University of Connecticut Health Center, Farmington, CT.
  • Wolfinger GJ; Pi Dental Center at the Institute for Facial Esthetics, Fort Washington, PA.
  • Kuo CL; Department of Community Medicine and Health Care, University of Connecticut Health Center, Farmington, CT.
J Prosthodont ; 28(8): 861-867, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31435989
PURPOSE: To examine if an uncorrected radiographically detected immediate postoperative misfit (implant level or abutment level) in immediately loaded conversion prosthesis plays a significant role in early implant or prosthesis failure. In addition, clinical characteristics related to type of arch, implant position, type of implant, implant orientation, type of connection, and type of surgery were analyzed relative to their relationship to early implant or prosthesis failure. MATERIALS AND METHODS: Immediate postoperative and subsequent follow-up panoramic radiographs of 425 arches with immediately loaded complete-arch fixed implant-supported prostheses were screened in a retrospective analysis. Implants with misfit and nonmisfit within a given arch were summarized separately with respect to each clinical characteristic and the difference between misfit and nonmisfit groups was tested using a mixed-effects logistic regression model with a patient-specific random intercept. A p-value <0.05 was determined to be statistically significant. RESULTS: A total of 2025 implants from 311 patients were identified in the 425 arches that were screened for radiographic misfit. A total of 48 implants with misfit were found within 33 arches (23 patients) for a 2.4% prevalence rate. Among the misfit implants, two failures were documented during the healing phase for an early implant survival rate of 95.8%. Five conversion prostheses with misfit fractured during the healing phase for early prosthesis survival rate of 84.8%. None of the clinical variables analyzed were significantly associated with the misfit status (p < 0.05). CONCLUSIONS: The results from this retrospective study showed that misfit in immediately loaded complete-arch fixed implant-supported prostheses may not play a detrimental role in the implant survival but may affect survival of the conversion prostheses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Arcada Edêntula / Carga Imediata em Implante Dentário Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Arcada Edêntula / Carga Imediata em Implante Dentário Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de publicação: Estados Unidos