Your browser doesn't support javascript.
loading
Mechanical Study of the Properties of Sutures used in Orthopedics Surgeries.
Gomide, Leandro Cardoso; Campos, Dagoberto de Oliveira; Araújo, Cleudmar Amaral; Menegaz, Gabriela Lima; Cardoso, Rafael Silva; Saad Júnior, Sérgio Crosara.
Afiliação
  • Gomide LC; Departamento de Cirurgia, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
  • Campos DO; Departamento de Cirurgia, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
  • Araújo CA; Faculdade de Engenharia Mecânica, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
  • Menegaz GL; Faculdade de Engenharia Mecânica, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
  • Cardoso RS; Departamento de Cirurgia, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
  • Saad Júnior SC; Departamento de Cirurgia, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
Rev Bras Ortop (Sao Paulo) ; 54(3): 247-252, 2019 May.
Article em En | MEDLINE | ID: mdl-31363277
Objective To evaluate the mechanical properties of sutures commonly used in orthopedic surgeries, characterizing their behavior through tensile tests and determining which one has greater mechanical strength. Method Tensile tests of different sutures were performed in a mechanical testing machine BME 10 kN, using a 50 kgf maximum capacity loading cell. Seven samples from each suture material were tested. Both ends of the sample material were fixed in the proper metal claw, maintaining an initial length of 5 cm. Tests were performed at a speed of 20 mm/minute and at room temperature, recording data for maximum displacement and maximum force at the rupture point. Results FiberWire® #2 (Artrhex, Naples, FL, USA) presented the highest mean strength of rupture (240.17 N), followed by HiFi® #2 (Conmed, Utica, NY, USA) (213.39N) and Ethibond® #5 (Ethicon Inc., Somerville, NJ, USA) (207.38 N). Ethibond® #2 (Ethicon Inc., Somerville, NJ, USA) had the lowest mean strength of rupture (97.8 N). Conclusion Non-absorbable braided polyblend sutures, more recently introduced, are superior to conventional, braided polyester sutures, and FiberWire® #2 is the most resistant suture evaluated in the present study.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Aspecto: Ethics Idioma: En Revista: Rev Bras Ortop (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Aspecto: Ethics Idioma: En Revista: Rev Bras Ortop (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha