Your browser doesn't support javascript.
loading
Development of new analytical method for preconcentration/speciation of inorganic antimony in bottled mineral water using FIA-HG AAS system and SiO2/Al2O3/SnO2 ternary oxide.
de Oliveira, Leandro Luan Gonçalves; Ferreira, Guilherme Orlandin; Suquila, Fabio Antonio Cajamarca; de Almeida, Fernanda Garcia; Bertoldo, Letícia Alana; Segatelli, Mariana Gava; Ribeiro, Emerson Schwingel; Tarley, César Ricardo Teixeira.
Afiliação
  • de Oliveira LLG; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • Ferreira GO; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • Suquila FAC; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • de Almeida FG; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • Bertoldo LA; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • Segatelli MG; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil.
  • Ribeiro ES; Grupo LaDANM, Instituto de Química, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ 21941-909, Brazil; Unesp, Instituto Nacional de Tecnologias Alternativas para Detecção, Avaliação Toxicológica e Remoção de Micropoluentes e Radioativos (INCT-DATREM), Instituto de Química, Caixa Po
  • Tarley CRT; Departamento de Química, Universidade Estadual de Londrina (UEL), Londrina, PR 86051-990, Brazil; Instituto Nacional de Ciência e Tecnologia (INCT) em Bioanalítica, Departamento de Química Analítica, Instituto de Química, Universidade Estadual de Campinas (UNICAMP), 13083-970 Campinas, SP, Brazil. E
Food Chem ; 294: 405-413, 2019 Oct 01.
Article em En | MEDLINE | ID: mdl-31126481
In the present paper, a new analytical preconcentration/speciation method for antimony species determination in bottled mineral water samples using the SiO2/Al2O3/SnO2 adsorbent was developed. The method is based on selective adsorption of Sb(III) ions by SiO2/Al2O3/SnO2 under a wide pH range (2.5-7.5). Total antimony was determined with previous sample treatment using 0.1% (w/v) l-cysteine and the concentration of Sb(V) species was determined by the difference between total and Sb(III). The proposed method provided an analytical curve ranging from 0.50 to 5.00 µg L-1 (r = 0.999), limit of detection (LD) of 0.17 µg L-1 and preconcentration factor (PF) of 136-fold. The method exhibited tolerance to different metal ions and the accuracy was attested from addition and recovery tests (95.2-106.0%) in bottled mineral water samples using 2.0% (w/v) l-cysteine, as well as by analysis of certified material. Only Sb(III) species were determined in mineral water (0.54-1.04 µg L-1).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Água Potável / Águas Minerais / Antimônio Idioma: En Revista: Food Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Água Potável / Águas Minerais / Antimônio Idioma: En Revista: Food Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido