Most frequent errors in inhalation technique of patients with asthma treated at a tertiary care hospital.
Pessôa, Carlos Leonardo Carvalho; Mattos, Maria Julia da Silva; Alho, Artur Renato Moura; Fischmann, Marianna Martini; Haerdy, Bruno Mendes; Côrtes, Ana Carolina Castro; Mendes, Flávio de Oliveira; Brignol, Sandra Mara Silva.
Afiliação
  • Pessôa CLC; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Mattos MJDS; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Alho ARM; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Fischmann MM; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Haerdy BM; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Côrtes ACC; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Mendes FO; Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Brignol SMS; Universidade Federal Fluminense, Niterói, RJ, Brazil.
Einstein (Sao Paulo) ; 17(2): eAO4397, 2019 May 02.
Article em En, Pt | MEDLINE | ID: mdl-31066791
OBJECTIVE: To demonstrate the most frequent errors in inhalation technique in patients with asthma undergoing treatment at a tertiary care hospital. METHODS: A cross-sectional study with a convenience sample of asthma patients aged 18 years or over, treated at a pulmonology outpatient clinic of a tertiary care hospital. The assessment of inhalation technique of users of the dry powder inhalers Aerolizer®, Aerocaps and Diskus®, or metered-dose inhalers was based on the manufacturer's instructions for use of each inhaler device. Patients demonstrated the inhalation technique with empty inhaler devices, and it was considered correct when all stages were performed properly, or when errors probably did not interfere with the treatment outcome. RESULTS: Among 71 participants, 43 (60.5%) performed inhalation technique incorrectly. Among metered-dose inhalers and dry powder inhalers users, inhalation technique errors were found in 84.2% and 51.9%, respectively (p=0.013). Errors were more frequent at the exhalation stage (67.4%), followed by breathing in (58.1%) and apnea (51.2%). In the group using dry powder inhalers, the most common errors occurred during exhalation and, for those using metered-dose inhalers, the most compromised stage was aspiration. CONCLUSION: Errors were more frequent among those using metered-dose inhalers compared with dry powder inhalers. Misconceptions are more common at the expiration stage among users of dry powder inhalers and in aspiration among those on metered-dose inhalers.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Administração por Inalação / Erros de Medicação Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / Pt Revista: Einstein (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Administração por Inalação / Erros de Medicação Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / Pt Revista: Einstein (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil