Your browser doesn't support javascript.
loading
A novel and low-complexity peak detection algorithm for heart rate estimation from low-amplitude photoplethysmographic (PPG) signals.
Argüello Prada, Erick Javier; Serna Maldonado, Rafael Daniel.
Afiliação
  • Argüello Prada EJ; a Departamento de Tecnologías de la Información y las Comunicaciones , Facultad de Ingeniería, Universidad Santiago de Cali , Santiago de Cali , Colombia.
  • Serna Maldonado RD; a Departamento de Tecnologías de la Información y las Comunicaciones , Facultad de Ingeniería, Universidad Santiago de Cali , Santiago de Cali , Colombia.
J Med Eng Technol ; 42(8): 569-577, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30920315
Low-amplitude PPG signals are more affected by noise contamination and other undesirable effects because the signal strength is comparable to noise power. Although several authors claim that decreases in the amplitude of the PPG wave should be addressed from signal acquisition and conditioning stages such decreases can also be associated with changes in the patient condition. In that instance, it is important to ensure continuous and reliable HR monitoring which, in turn, depends on how robust is the peak detection method. Numerous efforts have been made to develop algorithms for accurate PPG peak detection under high motion artefact conditions. However, little has been done regarding peak detection in low-amplitude PPG signals. In an attempt to address this issue, a novel and simple peak detection algorithm for PPG signals was proposed. Results show that our method could be a good contribution for robust strategies that can dynamically adapt their peak detection method to circumstances in which a decrease in the amplitude of the PPG signal is expected. Still, more extensive testing under a wide range of conditions (e.g. intensive physical exercise) is needed to perform a rigorous validation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Fotopletismografia / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Eng Technol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Fotopletismografia / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Eng Technol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Reino Unido