Your browser doesn't support javascript.
loading
Outpatient treatment for haemophilic arthropathy with radiosynovectomy: Radiation dose to family members.
Oliveira, Susie; Thomas, Sylvia; Dos Santos, Clara Lorena Glória; Berdeguez, Mirta Barbara Torres; de Sa, Lidia Vasconcellos; de Souza, Sergio Augusto Lopes.
Afiliação
  • Oliveira S; Radiology Departament, Clementino Fraga Filho University Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • Thomas S; Nuclear Medicine Department, Clementino Fraga Filho University Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • Dos Santos CLG; Nuclear Medicine Department, Clementino Fraga Filho University Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • Berdeguez MBT; Nuclear Engineering Department, Alberto Luiz Coimbra Institute of Post Graduation and Engineering Research, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • de Sa LV; Medical Physics Department, Radiation Protection and Dosimetry Institute, Rio de Janeiro, Brazil.
  • de Souza SAL; Radiology Departament, Clementino Fraga Filho University Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
Haemophilia ; 25(3): 509-513, 2019 May.
Article em En | MEDLINE | ID: mdl-30866133
One of the key features of good practice in medicine is the doctor-patient communication. Radiation protection standards for radiosynovectomy (RS) is limited. Yttrium-90 is a beta-emitting radioisotope used in RS to treat joint pain from haemophilic arthritis. ICRP 94 states that if a patient is treated with up to 200 MBq, there is no need for further precautions when it comes to public exposure, however, activities can go up to 370 MBq in RS for the knee. This study analysed 119 family members' safety (16.7% pregnant women). The ambient dose equivalent rate was measured within four distances. A survey was carried analysing risk groups and time spent next to patients. Results showed that family members should be advised to remain at 1.0 m from the patient to decrease accumulated dose by 97.6%. The dose per activity factors estimated in this study is also a useful tool during the risk assessment and doctor/patient communication. Pamphlets were distributed with radiation protection recommendations. Ambient dose equivalent was low enough to show that RS is a safe procedure for family members, which is essential to promote adherence to RS in countries where it is needed but not performed due to lack of information on radiation safety.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pacientes Ambulatoriais / Artrite / Doses de Radiação / Família / Sinovectomia / Hemofilia A Tipo de estudo: Guideline / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Haemophilia Assunto da revista: HEMATOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pacientes Ambulatoriais / Artrite / Doses de Radiação / Família / Sinovectomia / Hemofilia A Tipo de estudo: Guideline / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Haemophilia Assunto da revista: HEMATOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido