Your browser doesn't support javascript.
loading
Design and Development of a Bio-Inspired UHF Sensor for Partial Discharge Detection in Power Transformers.
Nobrega, Luiz A M M; Xavier, George V R; Aquino, Marcus V D; Serres, Alexandre J R; Albuquerque, Camila C R; Costa, Edson G.
Afiliação
  • Nobrega LAMM; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. luiz.nobrega@ee.ufcg.edu.br.
  • Xavier GVR; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. george.xavier@ee.ufcg.edu.br.
  • Aquino MVD; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. marcus.aquino@ee.ufcg.edu.br.
  • Serres AJR; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. alexandreserres@dee.ufcg.edu.br.
  • Albuquerque CCR; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. camila.albuquerque@ee.ufcg.edu.br.
  • Costa EG; Department of Electrical Engineering, Universidade Federal de Campina Grande, Aprigio Veloso 882, Campina Grande 58429-900, Brazil. edson@dee.ufcg.edu.br.
Sensors (Basel) ; 19(3)2019 Feb 05.
Article em En | MEDLINE | ID: mdl-30764540
In this paper, the design and development of a bio-inspired UHF sensor for partial discharge detection in power transformers is presented. The UHF sensor was developed for external use in dielectric windows of power transformers. For this purpose, a microstrip antenna was designed with a radiating element shape based on the leaf of the Jatropha mollissima (Pohl) Baill plant. Then, an epoxy coating and an aluminium enclosure were developed to protect the antenna against corrosion and to provide mechanical support, external noise immunity, and a lifetime compatibility with power transformers. In order to verify the electrical parameters of the developed sensor, measurements of the gain and the reflection coefficient were performed in an anechoic chamber. Lastly, the antenna sensitivity for denominated partial discharge (PD) detection was compared with the IEC 60270 standard method. For this purpose, simultaneous tests were carried out in a partial discharge generator setup, composed of an oil cell with needle-plane electrodes. The experimental tests demonstrated the effectiveness of the sensor for detecting PD signals with apparent charge values higher than 35 pC.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Suíça