Behavior of an Inductive Loop Sensor in the Measurement of Partial Discharge Pulses with Variations in Its Separation from the Primary Conductor.
Ardila-Rey, Jorge Alfredo; Barrueto, Aldo; Zerene, Alvaro; Castro, Bruno Albuquerque de; Ulson, José Alfredo Covolan; Mas'ud, Abdullahi Abubakar; Valdivia, Patricio.
Afiliação
  • Ardila-Rey JA; Department of Electrical Engineering, Universidad Técnica Federico Santa María, Av. Vicuña Mackenna 3939, 8940000 Santiago, Chile. jorge.ardila@usm.cl.
  • Barrueto A; Department of Electrical Engineering, Universidad Técnica Federico Santa María, Av. Vicuña Mackenna 3939, 8940000 Santiago, Chile. aldo.barrueto@usm.cl.
  • Zerene A; Department of Electrical Engineering, Universidad Técnica Federico Santa María, Av. Vicuña Mackenna 3939, 8940000 Santiago, Chile. alvaro.zerene@alumnos.usm.cl.
  • Castro BA; Department of Electrical Engineering, São Paulo State University, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru, Brazil. bruno.castro@unesp.br.
  • Ulson JAC; Department of Electrical Engineering, São Paulo State University, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru, Brazil. alfredo.ulson@unesp.br.
  • Mas'ud AA; Department of Electrical and Electronics Engineering, Jubail Industrial College, P.O. Box 10099, 319261 Jubail, Saudi Arabia. abdullahi.masud@gmail.com.
  • Valdivia P; Department of Electrical Engineering, Universidad Técnica Federico Santa María, Av. Vicuña Mackenna 3939, 8940000 Santiago, Chile. patricio.valdivial@usm.cl.
Sensors (Basel) ; 18(7)2018 Jul 18.
Article em En | MEDLINE | ID: mdl-30021944
Ideally, an insulation system must be capable of electrically insulating the active components of a machine or device subjected to high voltages. However, due to the presence of polluting agents or imperfections inside or on the surface of the insulation, small current pulses called partial discharges (PDs) are common, which partially short-circuit the insulation and cause it to lose its insulating properties, and thus its insulation capacity, over time. In some cases, measurements of this phenomenon are limited by the type of sensor used; if it is not adequate, it can distort the obtained results, which can lead to a misdiagnosis of the state of the device. The inductive loop sensor has experimentally been demonstrated to be capable of properly measuring different types of PDs. However, because of its current design, there are several practical limitations on its use in real devices or environments. An example is the presence of a primary conductor located at a fixed distance from the sensor, through which PD pulses must flow for the sensor to capture them. In this article, the sensor's behavior is studied at different separation distances from the line through which the PD pulses flow. In addition, the measuring capacity of the sensor is tested by removing the presence of the primary conductor and placing the sensor directly over the line through which the PD pulses of a real device flow.