Your browser doesn't support javascript.
loading
Label-Free Graphene Oxide-Based Surface Plasmon Resonance Immunosensor for the Quantification of Galectin-3, a Novel Cardiac Biomarker.
Primo, Emiliano N; Kogan, Marcelo J; Verdejo, Hugo E; Bollo, Soledad; Rubianes, María D; Rivas, Gustavo A.
Afiliação
  • Primo EN; INFIQC (CONICET), Haya de la Torre s/n, Ciudad Universitaria , X5000HUA Córdoba , Argentina.
  • Kogan MJ; Departamento de Fisicoquímica, Facultad de Ciencias Químicas , Universidad Nacional de Córdoba, Ciudad Universitaria , X5000HUA Córdoba , Argentina.
  • Verdejo HE; Advanced Center for Chronic Diseases (ACCDiS), Facultad de Ciencias Químicas y Farmacéuticas, Departamento de Química Farmacológica y Toxicológica , Universidad de Chile , 8380492 Santiago , Chile.
  • Bollo S; Advanced Center for Chronic Diseases (ACCDiS), División de Enfermedades Cardiovasculares, Facultad de Medicina , Pontificia Universidad Católica de Chile , 7500011 Santiago , Chile.
  • Rubianes MD; Advanced Center for Chronic Diseases (ACCDiS), Facultad de Ciencias Químicas y Farmacéuticas, Departamento de Química Farmacológica y Toxicológica , Universidad de Chile , 8380492 Santiago , Chile.
  • Rivas GA; INFIQC (CONICET), Haya de la Torre s/n, Ciudad Universitaria , X5000HUA Córdoba , Argentina.
ACS Appl Mater Interfaces ; 10(28): 23501-23508, 2018 Jul 18.
Article em En | MEDLINE | ID: mdl-29985579
We report the first optical biosensor for the novel and important cardiac biomarker, galectin-3 (Gal3), using the anti-Gal3 antibody as a biorecognition element and surface plasmon resonance (SPR) for transducing the bioaffinity event. The immunosensing platform was built at a thiolated Au surface modified by self-assembling four bilayers of poly(diallyldimethylammonium chloride) and graphene oxide (GO), followed by the covalent attachment of 3-aminephenylboronic acid (3ABA). The importance of GO, both as the anchoring point of the antibody and as a field enhancer for improving the biosensor sensitivity, was critically discussed. The advantages of using 3ABA to orientate the anti-Gal3 antibody through the selective link to the Fc region were also demonstrated. The new platform represents an interesting alternative for the label-free biosensing of Gal3 in the whole range of clinically relevant concentrations (linear range between 10.0 and 50.0 ng mL-1, detection limit of 2.0 ng mL-1) with successful application for Gal3 biosensing in enriched human serum samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ressonância de Plasmônio de Superfície Limite: Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ressonância de Plasmônio de Superfície Limite: Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos