A paper platform for colorimetric determination of aluminum hydrochloride in antiperspirant samples.
Silvestre, Amanda Letícia Polli; Milani, Maria Izabel; Rossini, Eduardo Luiz; Pezza, Leonardo; Pezza, Helena Redigolo.
Afiliação
  • Silvestre ALP; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil.
  • Milani MI; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil.
  • Rossini EL; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil.
  • Pezza L; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil.
  • Pezza HR; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil. Electronic address: hr.pezza@unesp.br.
Spectrochim Acta A Mol Biomol Spectrosc ; 204: 432-435, 2018 Nov 05.
Article em En | MEDLINE | ID: mdl-29966896
A simple, fast, low-cost, portable, and eco-friendly method using a spot test on a paper platform, together with diffuse reflectance spectroscopy, was developed and validated for the quantification of aluminum hydrochloride, a potential neurotoxic agent, in antiperspirant samples. The determination of aluminum hydrochloride was performed at a wavelength of 615 nm, by measuring consumption of the purple colorimetric reagent Alizarin S, due to reaction with aluminum. The linear range was from 10.0 to 125.0 mg L-1 and could be described by the equation: AR = 0.4479 - 0.002543 CAl (R = 0.999). The limits of detection (LOD) and quantification (LOQ) were 3.06 and 10.2 mg L-1, respectively. The method was specific, accurate, and repeatable, with relative standard deviation (RSD) <5.0%. The recovery was between 92.2 and 103.4%. The method was successfully used for the determination of aluminum hydrochloride in commercial antiperspirant samples, revealing concentrations below the maximum permitted by current legislation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloretos / Colorimetria / Compostos de Alumínio / Antiperspirantes Tipo de estudo: Prognostic_studies Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloretos / Colorimetria / Compostos de Alumínio / Antiperspirantes Tipo de estudo: Prognostic_studies Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido