Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS).
Artifon, Everson L A; Cheng, Spencer; Nakadomari, Thaisa; Kashiwagi, Leandro; Celso Ardengh, Jose; Belmonte, Emilio; Otoch, Jose P.
Afiliação
  • Artifon ELA; Department of Surgery, University of São Paulo Faculty of Medicine. São Paulo, Brazil.
  • Cheng S; Department of Surgery, University of São Paulo Faculty of Medicine. São Paulo, Brazil.
  • Nakadomari T; Department of Surgery and Endoscopy, Cajuru University Hospital. Curitiba, Brazil.
  • Kashiwagi L; Department of Surgery and Endoscopy, Cajuru University Hospital. Curitiba, Brazil.
  • Celso Ardengh J; Department of Surgery and Anatomy, University of São Paulo. Ribeirão Preto, Brazil.
  • Belmonte E; Fundação Pio XII, Hospital de Câncer de Barretos. São Paulo, Brazil; Ircad América Latina. São Paulo, Brazil.
  • Otoch JP; Department of Surgery, University of São Paulo Faculty of Medicine. São Paulo, Brazil.
Rev Gastroenterol Peru ; 38(1): 103-110, 2018.
Article em En | MEDLINE | ID: mdl-29791430
BACKGROUND: Endoscopic ultrasound training has a learning curve greater than the other endoscopic therapeutic techniques. One of the preclinical teaching methods is the use of ex vivo porcine models. AIM: To describe five ex vivo porcine models for training in therapeutic echoendoscopic procedures. MATERIALS AND METHODS: Using porcine digestive tract containing esophagus, stomach, duodenum, spleen, liver and gallbladder, five models for therapeutic echoendoscopy training were described. With other segments of the porcine pieces (such as the bladder, spleen segment and omentum segment) and with easily accessible materials (such as grape and ultrasound gel), lesions were simulated to be treated. These models were applied in the Hands on course at the IRCAD (Institut de recherche contre les cancers de l'appareil digestif) Barretos of 2017. Endoscopic equipment and instruments are the same as those used in clinical practice. RESULT: The models are easily reproducible and do not require exchange during the hands on course period. Endoscopic and echographic imaging and tactile sensitivity are similar to the real one. CONCLUSION: The models described in this study demonstrated to be realistic, easy to reproduce and allow repetition during the same session. However, comparative studies are necessary to verify the real impact on teaching.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Suínos / Endossonografia / Modelos Animais / Sistema Digestório / Treinamento por Simulação / Gastroenterologia Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Rev Gastroenterol Peru Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Peru
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Suínos / Endossonografia / Modelos Animais / Sistema Digestório / Treinamento por Simulação / Gastroenterologia Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Rev Gastroenterol Peru Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Peru