Your browser doesn't support javascript.
loading
Clavicle Kirschner Wire Migration into Left Lung: A Case Report.
Reghine, Érica Lofrano; Cirino, Caio César Inaco; Neto, André Amate; Varallo, Fabiana Rossi; Évora, Paulo Roberto Barbosa; de Nadai, Tales Rubens.
Afiliação
  • Reghine ÉL; Américo Brasiliense State Hospital, São Paulo, SP, Brazil.
  • Cirino CCI; Américo Brasiliense State Hospital, São Paulo, SP, Brazil.
  • Neto AA; Américo Brasiliense State Hospital, São Paulo, SP, Brazil.
  • Varallo FR; Américo Brasiliense State Hospital, São Paulo, SP, Brazil.
  • Évora PRB; Department of Surgery and Anatomy, Ribeirão Preto School of Medicine, University of São Paulo, São Paulo, SP, Brazil.
  • de Nadai TR; Américo Brasiliense State Hospital, São Paulo, SP, Brazil.
Am J Case Rep ; 19: 325-328, 2018 Mar 21.
Article em En | MEDLINE | ID: mdl-29559613
BACKGROUND Kirschner wires are often used to perform osteosynthesis. Migration through tissue of these wires is a rare but well-known occurrence. CASE REPORT A 65-year-old female presented with light intensity pain complaints in the upper left chest area; personal history included left clavicle fracture 20 years ago that was treated surgically with fixation using a K-wire. Chest radiography showed the presence of metallic foreign body in the left pulmonary apex. An exploratory axillary thoracotomy was performed, and the foreign body was extracted by a pneumotomy. CONCLUSIONS To obtain satisfactory results with a K-wire, some peculiarities in their application should be respected. The time from orthopedic surgery of the collarbone to migration into the chest of the metal rod used can vary from one day to nearly 20 years. Although the migration mechanism remains unclear, it is likely that it involves shoulder movements, breathing movements, negative intrathoracic pressure, gravitational force, or local bone resorption. Caution should be exercised when orthopedic pins and wires are used for the fixation of fractures and dislocations of the shoulder girdle. If there is migration of the wire, it should be removed immediately to avoid sudden and fatal complications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fios Ortopédicos / Migração de Corpo Estranho / Clavícula / Fraturas Ósseas / Fixação Interna de Fraturas / Pulmão Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans Idioma: En Revista: Am J Case Rep Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fios Ortopédicos / Migração de Corpo Estranho / Clavícula / Fraturas Ósseas / Fixação Interna de Fraturas / Pulmão Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans Idioma: En Revista: Am J Case Rep Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos