Your browser doesn't support javascript.
loading
Characterization of Bis-Acryl Composite Resins for Provisional Restorations.
Schwantz, Júlia K; Oliveira-Ogliari, Aline; Meereis, Carine T; Leal, Fernanda B; Ogliari, Fabrício A; Moraes, Rafael R.
Afiliação
  • Schwantz JK; School of Dentistry, UFPel - Universidade Federal de Pelotas, Pelotas, RS, Brazil.
  • Oliveira-Ogliari A; Graduate Program in Dentistry, UFPel - Universidade Federal de Pelotas, Pelotas, RS, Brazil.
  • Meereis CT; Graduate Program in Dentistry, UFPel - Universidade Federal de Pelotas, Pelotas, RS, Brazil.
  • Leal FB; Graduate Program in Dentistry, UFPel - Universidade Federal de Pelotas, Pelotas, RS, Brazil.
  • Ogliari FA; Graduate Program in Dentistry, UFPel - Universidade Federal de Pelotas, Pelotas, RS, Brazil.
  • Moraes RR; Engineering Materials School, UFPel - Universidade Federal de Pelotas, RS, Brazil.
Braz Dent J ; 28(3): 354-361, 2017.
Article em En | MEDLINE | ID: mdl-29297557
This study investigated the in vitro performance of the commercial bis-acryl composite resins Systemp C&B II (SYS, Ivoclar Vivadent), Protemp 4 (PT4, 3M ESPE), Structur 2C (ST2, Voco) and ProviPlast (PVP, Biodinamica). Characterization involved optical (color stability, translucency parameter, fluorescence), surface (roughness, morphology and elemental composition), physical-chemical (viscosity, polymerization kinetics) and mechanical analyses (Poisson ratio, biaxial flexural strength, flexural modulus). Most tests were carried out after 24 h, but optical and mechanical analyses were carried out after storage in water at 37 °C for 1, 15, and 30 days. Data were statistically analyzed (a=0.05). Most results were material dependent. SYS and PT4 showed stability in color and translucency over time. All materials had similar or higher fluorescence than human enamel. SC2 and PVP showed rougher surfaces than the other bis-acryl composites. Smaller filler particles were observed on the surface of PT4 and PVP compared with the coarser particles from ST2 and SYS. Viscosity readings indicated a thixotropic behavior for all tested materials. SYS had the lowest and PT4 the highest degree of C=C conversion after 10 min. In the polymerization kinetics, PT4 had the highest maximum polymerization rate and reached earlier the transition between polymerization autoacceleration and autodeceleration. PT4 and SYS had significantly higher flexural strength and modulus than ST2 and PVP for most storage times. Results for Poisson ratio varied between materials. Longer storage periods were generally associated with higher frequency of catastrophic failures in the flexural tests. In conclusion, the performance of bis-acryl composite resins varied largely among materials.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Restauração Dentária Temporária Limite: Humans Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Restauração Dentária Temporária Limite: Humans Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil