A new approach for radiosynoviorthesis: A dose-optimized planning method based on Monte Carlo simulation and synovial measurement using 3D slicer and MRI.
Torres Berdeguez, Mirta Bárbara; Thomas, Sylvia; Rafful, Patricia; Arruda Sanchez, Tiago; Medeiros Oliveira Ramos, Susie; Souza Albernaz, Marta; Vasconcellos de Sá, Lidia; Lopes de Souza, Sergio Augusto; Mas Milian, Felix; Silva, Ademir Xavier da.
Afiliação
  • Torres Berdeguez MB; Department of Nuclear Engineering, Federal University of Rio de Janeiro, Horácio Macedo Ave., 2030 Block G-Room 206, Technology Center,, University City, Fundão Island, 21941-914,, Rio de Janeiro, RJ, Brazil.
  • Thomas S; Department of Nuclear Medicine, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Rafful P; Department of Radiology, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Arruda Sanchez T; Department of Radiology, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Medeiros Oliveira Ramos S; Department of Nuclear Medicine, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Souza Albernaz M; Department of Nuclear Medicine, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Vasconcellos de Sá L; Institute of Radiation Protection and Dosimetry, Brazilian Nuclear Energy Commission, Salvador Allende Ave., s/n, Recreio dos Bandeirantes,, 22783-127,, Rio de Janeiro, RJ, Brazil.
  • Lopes de Souza SA; Department of Nuclear Medicine, Clementino Fraga Filho University Hospital of Federal University of Rio de Janeiro, Street Rodolpho Paulo Rocco, 255, University City, Fundão Island, 21941-913,, Rio de Janeiro, RJ, Brazil.
  • Mas Milian F; CPqCTR - Research Center for Radiation Sciences and Technology, State University of Santa Cruz, Rodovia Ilhéus-Itabuna, Km 16, Salobrinho, 45662000, Ilhéus, BA, Brazil.
  • Silva AXD; Department of Nuclear Engineering, Federal University of Rio de Janeiro, Horácio Macedo Ave., 2030 Block G-Room 206, Technology Center,, University City, Fundão Island, 21941-914,, Rio de Janeiro, RJ, Brazil.
Med Phys ; 44(7): 3821-3829, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28419533
PURPOSE: Recently, there has been a growing interest in a methodology for dose planning in radiosynoviorthesis to substitute fixed activity. Clinical practice based on fixed activity frequently does not embrace radiopharmaceutical dose optimization in patients. The aim of this paper is to propose and discuss a dose planning methodology considering the radiological findings of interest obtained by three-dimensional magnetic resonance imaging combined with Monte Carlo simulation in radiosynoviorthesis treatment applied to hemophilic arthropathy. METHOD: The parameters analyzed were: surface area of the synovial membrane (synovial size), synovial thickness and joint effusion obtained by 3D MRI of nine knees from nine patients on a SIEMENS AVANTO 1.5 T scanner using a knee coil. The 3D Slicer software performed both the semiautomatic segmentation and quantitation of these radiological findings. A Lucite phantom 3D MRI validated the quantitation methodology. The study used Monte Carlo N-Particle eXtended code version 2.6 for calculating the S-values required to set up the injected activity to deliver a 100 Gy absorbed dose at a determined synovial thickness. The radionuclides assessed were: 90Y, 32P, 188Re, 186Re, 153Sm, and 177Lu, and the present study shows their effective treatment ranges. RESULT: The quantitation methodology was successfully tested, with an error below 5% for different materials. S-values calculated could provide data on the activity to be injected into the joint, considering no extra-articular leakage from joint cavity. Calculation of effective treatment range could assist with the therapeutic decision, with an optimized protocol for dose prescription in RSO. CONCLUSION: Using 3D Slicer software, this study focused on segmentation and quantitation of radiological features such as joint effusion, synovial size, and thickness, all obtained by 3D MRI in patients' knees with hemophilic arthropathy. The combination of synovial size and thickness with the parameters obtained by Monte Carlo simulation such as effective treatment range and S-value, from which is calculated the injected activity, could be used for treatment planning in RSO. Data from this methodology could be a potential aid to clinical decision making by selecting the most suitable radionuclide; justifying the procedure, fractioning the dose, and the calculated injected activity for children and adolescents, considering both the synovial size and thickness.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Imageamento por Ressonância Magnética / Compostos Radiofarmacêuticos Tipo de estudo: Guideline / Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Imageamento por Ressonância Magnética / Compostos Radiofarmacêuticos Tipo de estudo: Guideline / Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos