Your browser doesn't support javascript.
loading
Use of exhaled air as an improved biomonitoring method to assess perchloroethylene short-term exposure.
Dias, Cláudia M; Menezes, Helvécio C; Cardeal, Zenilda L.
Afiliação
  • Dias CM; Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos 6627, 31270-901 Belo Horizonte, MG, Brazil.
  • Menezes HC; Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos 6627, 31270-901 Belo Horizonte, MG, Brazil.
  • Cardeal ZL; Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos 6627, 31270-901 Belo Horizonte, MG, Brazil. Electronic address: zenilda@ufmg.br.
Environ Res ; 156: 108-112, 2017 07.
Article em En | MEDLINE | ID: mdl-28342345
This paper shows the use of exhaled air as a biomonitoring method to assess perchloroethylene (PERC) environmental and occupational exposure. A sensitive, fast, and solvent free analytical method was developed to determine PERC in ambient and exhaled air of individuals occupationally exposed. The developed method used cold fiber solid phase microextraction (CF-SPME) as the sampling technique, and a standard permeation method to simulation of air matrix. The analysis were conducted by gas chromatography coupled to mass spectrometry (GC/MS). The methods were validated and were found to be precise, linear and sensitive for environmental and biological monitoring. The developed methods were applied to twenty-seven sampling points spread across Belo Horizonte city, Brazil, twenty four dry cleaners, an electroplating industry, a research laboratory, and an automotive paint preparation shop. The results of ambient air analyses ranging from 14.0 to 3205.0µgm-3 with median concentration of 599.0µgm-3. Furthermore, sampling of exhaled air of individuals occupationally exposed presented results ranging from 6.0 to 2635.0µgm-3 with median concentration of 325.0µgm-3. The strong correlation observed between ambient and exhaled air (r =0.930) demonstrates that exhaled air is a suitable biomarker for evaluating occupational exposure to PERC.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetracloroetileno / Monitoramento Ambiental / Exposição Ocupacional / Poluição do Ar em Ambientes Fechados / Expiração / Poluentes Ocupacionais do Ar Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: Environ Res Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetracloroetileno / Monitoramento Ambiental / Exposição Ocupacional / Poluição do Ar em Ambientes Fechados / Expiração / Poluentes Ocupacionais do Ar Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Revista: Environ Res Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda