Your browser doesn't support javascript.
loading
Measurement of the area of venous ulcers using two software programs.
Eberhardt, Thaís Dresch; Lima, Suzinara Beatriz Soares de; Lopes, Luis Felipe Dias; Borges, Eline de Lima; Weiller, Teresinha Heck; Fonseca, Graziele Gorete Portella da.
Afiliação
  • Eberhardt TD; Doctoral student, Departamento de Enfermagem, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil.
  • Lima SB; PhD, Adjunct Professor, Departamento de Enfermagem, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil.
  • Lopes LF; PhD, Associate Professor, Departamento de Administração, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil.
  • Borges EL; PhD, Associate Professor, Departamento de Enfermagem, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil.
  • Weiller TH; PhD, Adjunct Professor, Departamento de Enfermagem, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil.
  • Fonseca GG; Master's student, Departamento de Enfermagem, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil.
Rev Lat Am Enfermagem ; 24: e2862, 2016 12 19.
Article em En, Pt, Es | MEDLINE | ID: mdl-27992028
Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm².
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Úlcera Varicosa / Software / Diagnóstico por Computador Tipo de estudo: Diagnostic_studies Aspecto: Ethics Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En / Es / Pt Revista: Rev Lat Am Enfermagem Assunto da revista: ENFERMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Úlcera Varicosa / Software / Diagnóstico por Computador Tipo de estudo: Diagnostic_studies Aspecto: Ethics Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En / Es / Pt Revista: Rev Lat Am Enfermagem Assunto da revista: ENFERMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil