Your browser doesn't support javascript.
loading
Optical devices for the detection of cyanide in water based on ethyl(hydroxyethyl)cellulose functionalized with perichromic dyes.
Nandi, Leandro Guarezi; Nicoleti, Celso Rodrigo; Marini, Vanderléia Gava; Bellettini, Ismael Casagrande; Valandro, Silvano Rodrigo; Cavalheiro, Carla Cristina Schmitt; Machado, Vanderlei Gageiro.
Afiliação
  • Nandi LG; Departamento de Química, Universidade Federal de Santa Catarina, UFSC, CP 476, Florianópolis, SC, 88040-900, Brazil.
  • Nicoleti CR; Departamento de Química, Universidade Federal de Santa Catarina, UFSC, CP 476, Florianópolis, SC, 88040-900, Brazil.
  • Marini VG; Departamento de Química, Universidade Federal de Santa Catarina, UFSC, CP 476, Florianópolis, SC, 88040-900, Brazil.
  • Bellettini IC; Departamento de Química, Universidade Federal de Santa Catarina, UFSC, CP 476, Florianópolis, SC, 88040-900, Brazil.
  • Valandro SR; Departamento de Físico-Química, Instituto de Química de São Carlos, Universidade de São Paulo, USP, CP 780, São Carlos, SP, 13560-970, Brazil.
  • Cavalheiro CCS; Departamento de Físico-Química, Instituto de Química de São Carlos, Universidade de São Paulo, USP, CP 780, São Carlos, SP, 13560-970, Brazil.
  • Machado VG; Departamento de Química, Universidade Federal de Santa Catarina, UFSC, CP 476, Florianópolis, SC, 88040-900, Brazil. Electronic address: vanderlei.machado@ufsc.br.
Carbohydr Polym ; 157: 1548-1556, 2017 Feb 10.
Article em En | MEDLINE | ID: mdl-27987867
Films of three polymers, based on ethyl(hydroxyethyl)cellulose functionalized with protonated perichromic dyes, were used for anion sensing. The polymer functionalized with protonated Brooker's merocyanine acts as a chromogenic/fluorogenic system for the selective detection of cyanide in water. An increase of >28 times was verified for the fluorescence lifetime of the sensing units in the polymer in comparison with protonated Brooker's merocyanine in water. Moreover, an increase in the pKa values was verified for the sensing units in the polymers. Data suggest that the hydrocarbonic polymeric chains provide an adequate microenvironment to protect the sensing unit from bulk water. The other polymer, functionalized with an iminophenol, also showed high selectivity for cyanide (detection limit=9.36×10-6molL-1 and quantification limit=3.12×10-5molL-1). The polymer functionalized with azophenol units is unable for the detection of cyanide, due to the low pKa value verified for its chromogenic units.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Carbohydr Polym Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Carbohydr Polym Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido