Use of cross-reactivity immunoassay to orient insulin replacement in diabetic patients with high levels of insulin antibodies.
Cardoso Landaburu, Alejandro; Pomares, María; Avalos, Alfredo; Lapertosa, Silvia; Frechtel, Gustavo; Poskus, Edgardo.
Afiliação
  • Cardoso Landaburu A; Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Cátedra de Inmunología-IDEHU (UBA-CONICET), Buenos Aires, Junín 956, CABA, CP C1113AAD, Argentina.
  • Pomares M; Servicio de Endocrinología y Diabetes del Hospital Juan Pablo II, San Martin 569 Corrientes Capital CP 3400, Argentina.
  • Avalos A; Servicio de Endocrinología, Nutrición y Diabetes, Hospital J. R. Vidal, Necochea 1050, Corrientes Capital CP 3400, Argentina.
  • Lapertosa S; Servicio de Endocrinología, Nutrición y Diabetes, Hospital J. R. Vidal, Necochea 1050, Corrientes Capital CP 3400, Argentina.
  • Frechtel G; Servicio de Nutrición, Departamento de Medicina, Facultad de Medicina, Universidad de Buenos Aires (UBA), Paraguay 2155, CABA C1121ABG, Argentina.
  • Poskus E; Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Cátedra de Inmunología-IDEHU (UBA-CONICET), Buenos Aires, Junín 956, CABA, CP C1113AAD, Argentina.
MethodsX ; 3: 502-7, 2016.
Article em En | MEDLINE | ID: mdl-27617231
The prevalence and high levels of anti-insulin antibodies (IA) have frequently been associated with brittle diabetes, lipodystrophy in the areas where the insulin is injected and/or poor metabolic control. When this happens the usual criterion adopted is the empirical change of insulin type and/or formulation intending to diminish the IA level and then to decrease the undesirable side-effects. Here, we present a rational two step radiometric method consisting in: A) a first-line radioligand binding assay (RBA) to assess IA in sera of these patients and detecting those with high levels. B) applying a displacement assay (RIA) to determine the in vitro cross-reactivity parameters (affinity constants and selectivity ratios) that quantify the relative degree of interaction between antibodies and alternative insulin analogs. From these results we conclude that conventional criteria for selection of insulin analogs, in terms of pharmacokinetic and pharmacodinamic parameters, should be complemented with an appropriate test to assess affinity parameters when high IA title is demonstrated. •This manuscript introduces a rational method to determine the appropriated insulin replacement when high insulin antibodies levels are present.•This protocol provides instructions and details in mathematical tools and laboratory processes for the analysis of serum samples.•This method proved to be successful in a single case and requires confirmation using a large group of patients.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Revista: MethodsX Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Argentina País de publicação: Holanda