Bispectral Index Monitoring in Patients Undergoing Open Heart Surgery.
Kabukcu, Hanife Karakaya; Sahin, Nursel; Ozkaloglu, Kezban; Golbasi, Ilhan; Titiz, Tulin Aydogdu.
Afiliação
  • Kabukcu HK; Medical Faculty, Akdeniz University, Antalya, Turkey.
  • Sahin N; Medical Faculty, Akdeniz University, Antalya, Turkey.
  • Ozkaloglu K; Medical Faculty, Akdeniz University, Antalya, Turkey.
  • Golbasi I; Medical Faculty, Akdeniz University, Antalya, Turkey.
  • Titiz TA; Medical Faculty, Akdeniz University, Antalya, Turkey.
Braz J Cardiovasc Surg ; 31(2): 178-82, 2016 04.
Article em En | MEDLINE | ID: mdl-27556320
INTRODUCTION: To obtain the optimal anesthesia depth is not easy in cardiovascular surgery patients where the haemodynamic reserve is limited, due to reasons such as not being able to give the desired dose of anesthetic agent, or the change in the pharmacokinetics of the agent in the heart-lung machine. This study was planned to assess the contribution of bispectral index (BIS) monitoring in the depth of anesthesia. METHODS: The patients were divided into 2 groups, and BIS monitoring was used for each patient. Group 1 (G1 n=35): keeping the BIS monitor screen open, the anesthesia need was set. Group 2 (G2 n=35): BIS monitor was tied to the patient and the monitor screen was closed in such a way that the anaesthesist couldn't see the BIS value. When the recording time came, the data on the monitor was recorded. The need for the anesthetic agent was set according to the parameters such as haemodynamics or follow up of pupils, instead of BIS value, by titrating the anesthetic infusion doses. RESULTS: BIS values were similar in both groups before the induction, BIS values in both groups showed a decrease, showing no significant statistical difference (P>0.05). One patient in each group said that he dreamt, and one patient in G2 said that he had heard a noise and felt that he was taken from one place to another. CONCLUSION: The management should be done with clinical evaluation, haemodynamics and other monitorization methods and BIS monitoring findings together.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ponte de Artéria Coronária / Monitorização Intraoperatória / Monitores de Consciência / Consciência no Peroperatório Limite: Aged / Humans / Middle aged Idioma: En Revista: Braz J Cardiovasc Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Turquia País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ponte de Artéria Coronária / Monitorização Intraoperatória / Monitores de Consciência / Consciência no Peroperatório Limite: Aged / Humans / Middle aged Idioma: En Revista: Braz J Cardiovasc Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Turquia País de publicação: Brasil