Your browser doesn't support javascript.
loading
Fast analysis of terbutaline in pharmaceuticals using multi-walled nanotubes modified electrodes from recordable compact disc.
Felix, Fabiana S; Daniel, Daniela; Matos, Jivaldo R; Lucio do Lago, Claudimir; Angnes, Lúcio.
Afiliação
  • Felix FS; Universidade de São Paulo, Instituto de Química, São Paulo, 05508-000, Brazil.
  • Daniel D; Universidade de São Paulo, Instituto de Química, São Paulo, 05508-000, Brazil; Agilent Technologies, Alameda Araguaia, 1142, CEP 06455-000, Barueri, SP, Brazil.
  • Matos JR; Universidade de São Paulo, Instituto de Química, São Paulo, 05508-000, Brazil.
  • Lucio do Lago C; Universidade de São Paulo, Instituto de Química, São Paulo, 05508-000, Brazil.
  • Angnes L; Universidade de São Paulo, Instituto de Química, São Paulo, 05508-000, Brazil. Electronic address: luangnes@iq.usp.br.
Anal Chim Acta ; 928: 32-38, 2016 Jul 20.
Article em En | MEDLINE | ID: mdl-27251854
In this study, homemade disposable gold electrodes made from recordable compact disks were modified with carbon nanotubes for amperometric quantification of terbutaline sulfate in pharmaceutical products. A flow cell using an impingent jet of solution on the electrode surface was build and used for amperometric detection, and a series of experiments were carried out to find the best experimental conditions for the new electrode in a specially designed cell. A linear response for terbutaline was obtained in the range from 3.0 × 10(-6) to 5.0 × 10(-4) mol L(-1) (at 0.63 V vs. Ag/AgCl). The limits of detection and quantification were calculated as 5.8 × 10(-7) mol L(-1) (S/N = 3) and 1.9 × 10(-6) mol L(-1) (S/N = 10), respectively. A frequency of 30 injections h(-1) was attained. The proposed method was successfully applied to the analyses of commercial syrup samples, and all results were in good agreement with those obtained by using high performance liquid chromatography and capillary electrophoresis-tandem mass spectrometry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terbutalina / Preparações Farmacêuticas / Discos Compactos / Nanotubos de Carbono / Eletroquímica / Limite de Detecção Idioma: En Revista: Anal Chim Acta Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terbutalina / Preparações Farmacêuticas / Discos Compactos / Nanotubos de Carbono / Eletroquímica / Limite de Detecção Idioma: En Revista: Anal Chim Acta Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda