Your browser doesn't support javascript.
loading
Novel analytical procedure using a combination of hollow fiber supported liquid membrane and dispersive liquid-liquid microextraction for the determination of aflatoxins in soybean juice by high performance liquid chromatography - Fluorescence detector.
Simão, Vanessa; Merib, Josias; Dias, Adriana N; Carasek, Eduardo.
Afiliação
  • Simão V; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil.
  • Merib J; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil.
  • Dias AN; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil.
  • Carasek E; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil. Electronic address: eduardo.carasek@ufsc.br.
Food Chem ; 196: 292-300, 2016 Apr 01.
Article em En | MEDLINE | ID: mdl-26593494
This study describes a combination between hollow fiber membrane and dispersive liquid-liquid microextraction for determination of aflatoxins in soybean juice by HPLC. The main advantage of this approach is the use of non-chlorinated solvent and small amounts of organic solvents. The optimum extraction conditions were 1-octanol as immobilized solvent; toluene and acetone at 1:5 ratio as extraction and disperser solvents (100 µL), NaCl at 2% of the sample volume and extraction time of 60 min. The optimal condition for the liquid desorption was 150 µL acetonitrile:water (50:50 v/v) and desorption time of 20 min. The linear range varied from 0.03 to 21 µg L(-1), with R(2) coefficients ranging from 0.9940 to 0.9995. The limits of detection and quantification ranged from 0.01 µg L(-1) to 0.03 µg L(-1) and from 0.03 µg L(-1) to 0.1 µg L(-1), respectively. Recovery tests ranged from 72% to 117% and accuracy between 12% and 18%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glycine max / Cromatografia Líquida de Alta Pressão / Aflatoxinas / Microextração em Fase Líquida Idioma: En Revista: Food Chem Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glycine max / Cromatografia Líquida de Alta Pressão / Aflatoxinas / Microextração em Fase Líquida Idioma: En Revista: Food Chem Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido