[Blood pressure measurement with Doppler in normal newborn infants and infants]. / Medición de presión arterial con Doppler en recién nacidos y lactantes normales.
Rev Chil Pediatr
; 60(1): 10-4, 1989.
Article
em Es
| MEDLINE
| ID: mdl-2634859
Systolic blood pressure (SBP) was measured by Doppler method in an aleatory sample of 251 healthy children from south-east Santiago Chile (131 females and 120 males) which were divided by age in five groups: 0 to 28 days (n = 5) 1 to 5 months (n = 48), 6 to 11 months (n = 48), 12 to 17 months (n = 46) and 18 to 24 months (n = 45). Great dispersion of SBP values occurred among newborn infants (range 85 to 125) in comparison with groups 1 to 5 months (105 to 130), 6 to 11 months (118 to 130). Fifty and 95 percentiles were, respectively, 107 to 125; 116 to 130; 121 to 130; 118 to 130 and 120 to 130. These values were greater than those obtained by sphygmomanometry in a similar matched group of children.