Your browser doesn't support javascript.
loading
A versatile x-ray microtomography station for biomedical imaging and materials research.
Lussani, Fernando Cesar; Vescovi, Rafael Ferreira da Costa; de Souza, Thaís Diniz; Leite, Carlos A P; Giles, Carlos.
Afiliação
  • Lussani FC; Instituto de Física "Gleb Wataghin," Universidade Estadual de Campinas, Campinas, São Paulo 13083-859, Brazil.
  • Vescovi RF; Instituto de Física "Gleb Wataghin," Universidade Estadual de Campinas, Campinas, São Paulo 13083-859, Brazil.
  • de Souza TD; Instituto de Física "Gleb Wataghin," Universidade Estadual de Campinas, Campinas, São Paulo 13083-859, Brazil.
  • Leite CA; Instituto de Física "Gleb Wataghin," Universidade Estadual de Campinas, Campinas, São Paulo 13083-859, Brazil.
  • Giles C; Instituto de Física "Gleb Wataghin," Universidade Estadual de Campinas, Campinas, São Paulo 13083-859, Brazil.
Rev Sci Instrum ; 86(6): 063705, 2015 Jun.
Article em En | MEDLINE | ID: mdl-26133842
An x-ray microtomography station implemented at the X-ray Applied Crystallography Laboratory of the State University of Campinas is described. The station is based on a propagation based phase contrast imaging setup with a microfocus source and digital x-ray area detectors. Due to its simplicity, this setup is ideal for fast, high resolution imaging and microtomography of small biological specimens and materials research samples. It can also be coupled to gratings to use and develop new techniques as the harmonic spatial coherent imaging, which allow scattering contrast imaging. Details of the experimental setup, equipment, and software integration are described. Test microtomography for setup commissioning and characterization is shown. We conclude that phase contrast enhanced x-ray imaging and microtomography with resolution below 5 µm voxel size are possible and data sets as wide as 2000 × 2000 × 2000 voxels are obtained with this instrumentation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microtomografia por Raio-X Limite: Animals Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microtomografia por Raio-X Limite: Animals Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos