Your browser doesn't support javascript.
loading
Polypropylene and polypropylene/polyglecaprone (Ultrapro®) meshes in the repair of incisional hernia in rats.
Utiyama, Edivaldo Massazo; Rosa, Maria Beatriz Sartor de Faria; Andres, Marina de Paula; Miranda, Jocielle Santos de; Damous, Sérgio Henrique Bastos; Birolini, Cláudio Augusto Vianna; Damous, Luciana Lamarão; Montero, Edna Frasson de Souza.
Afiliação
  • Utiyama EM; Department of Surgery, Medical School, Sao Paulo University, Brazil.
  • Rosa MB; Medical School, USP, Brazil.
  • Andres Mde P; Medical School, USP, Brazil.
  • Miranda JS; Department of Surgery, Medical School, USP, Brazil.
  • Damous SH; Department of Surgery, Medical School, USP, Brazil.
  • Birolini CA; Department of Surgery, Medical School, USP, Brazil.
  • Damous LL; Department of Obstetrics and Gynecology, Medical School, USP, Brazil.
  • Montero EF; Department of Surgery, Medical School, USP, Brazil.
Acta Cir Bras ; 30(6): 376-81, 2015 Jun.
Article em En | MEDLINE | ID: mdl-26108024
PURPOSE: To compare the inflammatory response of three different meshes on abdominal hernia repair in an experimental model of incisional hernia. METHODS: Median fascial incision and skin synthesis was performed on 30 Wistar rats. After 21 days, abdominal hernia developed was corrected as follows: 1) No mesh; 2) Polypropylene mesh; and, 3) Ultrapro(r) mesh. After 21 days, the mesh and surrounding tissue were submitted to macroscopic (presence of adhesions, mesh retraction), microscopic analysis to identify and quantify the inflammatory and fibrotic response using a score based on a predefined scale of 0-3 degrees, evaluating infiltration of macrophages, giant cells, neutrophils and lymphocytes. RESULTS: No significant difference was seen among groups in adherences, fibrosis, giant cells, macrophages, neutrophils or lymphocytes (p>0.05). Mesh shrinkage was observed in all groups, but also no difference was observed between polypropylene and Ultrapro mesh (7.0±9.9 vs. 7.4±10.1, respectively, p=0.967). Post-operatory complications included fistula, abscess, dehiscence, serohematic collection and reherniation, but with no difference among groups (p=0.363). CONCLUSION: There is no difference between polypropylene (high-density) and Ultrapro(r) (low-density) meshes at 21 days after surgery in extraperitoneal use in rats, comparing inflammatory response, mesh shortening, adhesions or complications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Polipropilenos / Telas Cirúrgicas / Dioxanos / Herniorrafia / Hérnia Ventral Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Acta Cir Bras Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Polipropilenos / Telas Cirúrgicas / Dioxanos / Herniorrafia / Hérnia Ventral Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Acta Cir Bras Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil