Your browser doesn't support javascript.
loading
Determination of Pinaverium Bromide in Human Plasma by a Sensitive and Robust UPLC-MS-MS Method and Application to a Pharmacokinetic Study in Mexican Subjects.
Patiño-Rodríguez, Omar; Zapata-Morales, Juan Ramón; Escobedo-Moratilla, Abraham; Díaz de León-Cabrero, Manuel; Torres-Roque, Irma; Pérez-Urizar, José.
Afiliação
  • Patiño-Rodríguez O; Dixpertia, Investigación Biofarmacéutica y Farmacológica S.C., San Luis Potosí, SLP, México.
  • Zapata-Morales JR; Dixpertia, Investigación Biofarmacéutica y Farmacológica S.C., San Luis Potosí, SLP, México.
  • Escobedo-Moratilla A; Dixpertia, Investigación Biofarmacéutica y Farmacológica S.C., San Luis Potosí, SLP, México.
  • Díaz de León-Cabrero M; Dixpertia, Investigación Biofarmacéutica y Farmacológica S.C., San Luis Potosí, SLP, México.
  • Torres-Roque I; Dixpertia, Investigación Biofarmacéutica y Farmacológica S.C., San Luis Potosí, SLP, México.
  • Pérez-Urizar J; Laboratorio de Farmacología y Fisiología, Facultad de Ciencias Químicas, UASLP, San Luis Potosí, SLP, México jpurizar@uaslp.mx.
J Chromatogr Sci ; 53(8): 1373-8, 2015 Sep.
Article em En | MEDLINE | ID: mdl-25862744
A high-throughput ultra-performance liquid chromatography coupled to tandem mass spectrometry (LC-ESI-MS-MS) method was developed for the determination of pinaverium bromide in human plasma. Protein precipitation with acetonitrile was used to extract pinaverium and itraconazole (as internal standard) from 500 µL plasma samples. The chromatographic separation was achieved with an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 100 mm) using a mixture of acetonitrile-5 mM ammonium formate (80:20, v/v) as mobile phase. Isocratic elution at 0.3 mL/min was used. Detection was performed by positive ion electrospray tandem mass spectrometry on a XEVO TQ-S by multiple reaction monitoring mode. The mass transitions monitorized were as follows: m/z 511.2 → 230 for pinaverium bromide, and m/z 705.29 → 392.18 for the itraconazole. The method was validated over a concentration range of 12-12,000 pg/mL. The chromatographic method runtime is 2.5 min and was applied to characterize the pharmacokinetics of pinaverium bromide after the oral administration of 100 mg to healthy Mexican subjects.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Morfolinas / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male País/Região como assunto: Mexico Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2015 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Morfolinas / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male País/Região como assunto: Mexico Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2015 Tipo de documento: Article País de publicação: Estados Unidos