Capillary zone electrophoresis method for the direct determination of amino acids in recombinant human erythropoietin preparations used for the treatment of anemia.
de Souza Crespo, Izabel Cristina; de Resende, Matheus Troina; Pereira Netto, Annibal Duarte; de Carvalho Marques, Flávia Ferreira.
Afiliação
  • de Souza Crespo IC; Instituto de Tecnologia em Imunobiológicos, Bio-Manguinhos, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brazil.
  • de Resende MT; Programa de Pós-Graduação em Química, Instituto de Química, Universidade Federal Fluminense, Niterói, RJ, Brazil.
  • Pereira Netto AD; Laboratório de Química Analítica Fundamental e Aplicada, Departamento de Química Analítica, Niterói, RJ, Brazil.
  • de Carvalho Marques FF; Programa de Pós-Graduação em Química, Instituto de Química, Universidade Federal Fluminense, Niterói, RJ, Brazil.
Electrophoresis ; 36(9-10): 1179-85, 2015 May.
Article em En | MEDLINE | ID: mdl-25753141
A method based on CZE for the determination of glutamic acid, glycine, and alanine in a biopharmaceutical formulation containing recombinant human erythropoietin was developed. The separation was achieved within less than 5 min, using a fused-silica capillary column (55 cm × 50 µm id) and 30 mmol/L phosphate buffer at pH 11.5, containing 0.6 mmol/L CTAB and 10% v/v methanol, as BGE solution. Applied potential of -25 kV, temperature of 15°C and hydrodynamic injection time of 15 s, at 50 mbar, were employed. The detection of the analytes was carried out without any derivatization reaction, at 220 nm using an UV-DAD detector. Linear ranges from 50 to 2500 mg/L and quantification limits of 40, 39, and 37 mg/L were obtained for glutamic acid, glycine, and alanine, respectively. Sample preparation required only a dilution step. Considering peak area and migration time values, the method presented good repeatability (RSD <1.7%; n = 9) and intermediate precision (RSD <1.0%; n = 6). Recovery evaluation using a commercial sample led to values between 97.5 ± 5.2% and 101.5 ± 4.6%, demonstrating the feasibility of the method, which was successfully applied in the quantification of the amino acids of interest in biopharmaceutical samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas Recombinantes / Eritropoetina / Aminoácidos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas Recombinantes / Eritropoetina / Aminoácidos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha