Your browser doesn't support javascript.
loading
Evaluation of an adsorption system to concentrate VOC in air streams prior to catalytic incineration.
Campesi, María A; Luzi, Carlos D; Barreto, Guillermo F; Martínez, Osvaldo M.
Afiliação
  • Campesi MA; Departamento de Ingeniería Química, Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP) 1 y 47, CP 1900 La Plata, Argentina; CINDECA, CCT La Plata (CONICET-UNLP), Calle 47 Nº 257, CP B1900AJK La Plata, Argentina.
  • Luzi CD; Departamento de Ingeniería Química, Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP) 1 y 47, CP 1900 La Plata, Argentina; CINDECA, CCT La Plata (CONICET-UNLP), Calle 47 Nº 257, CP B1900AJK La Plata, Argentina.
  • Barreto GF; Departamento de Ingeniería Química, Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP) 1 y 47, CP 1900 La Plata, Argentina; CINDECA, CCT La Plata (CONICET-UNLP), Calle 47 Nº 257, CP B1900AJK La Plata, Argentina.
  • Martínez OM; Departamento de Ingeniería Química, Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP) 1 y 47, CP 1900 La Plata, Argentina; CINDECA, CCT La Plata (CONICET-UNLP), Calle 47 Nº 257, CP B1900AJK La Plata, Argentina. Electronic address: osvaldommartinez@gmail.com.
J Environ Manage ; 154: 216-24, 2015 May 01.
Article em En | MEDLINE | ID: mdl-25734958
Catalytic combustion is a well-developed process for the removal of volatile organic compounds (VOCs). In order to reduce both the amount of catalyst needed for incineration and the surface area of recuperative heat exchangers, an evaluation of the use of thermal swing adsorption as a previous step for VOC concentration is made. An air stream containing ethyl acetate and ethanol (employed as solvents in printing processes) has been taken as a case study. Based on the characteristics of the adsorption/desorption system and the properties of the stream to be treated, a monolithic rotor concentrator with activated carbon as adsorbent material is adopted. Once the temperature of the inlet desorption stream TD is chosen, the minimum possible desorption flow rate, WD,min, and the amount of adsorbent material can be properly defined according to the extent of the Mass Transfer Zone (MTZ) at the end of the adsorption stage. An approximate procedure to speed up the calculations needed for sizing the bed and predicting the operating variables is also presented. In the case studied here, the concentration of the VOC stream can reach 6 times that of the primary effluent when TD = 200 °C is chosen.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Incineração / Poluentes Atmosféricos / Compostos Orgânicos Voláteis Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Environ Manage Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Incineração / Poluentes Atmosféricos / Compostos Orgânicos Voláteis Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Environ Manage Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido