Your browser doesn't support javascript.
loading
Microwave-induced combustion of crude oil for further rare earth elements determination by USN-ICP-MS.
Pereira, J S F; Pereira, L S F; Mello, P A; Guimarães, R C L; Guarnieri, R A; Fonseca, T C O; Flores, E M M.
Afiliação
  • Pereira JS; Departamento de Química Inorgânica, Universidade Federal do Rio Grande do Sul, 97105-900 Porto Alegre, RS, Brazil.
  • Pereira LS; Departamento de Química, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Mello PA; Departamento de Química, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Guimarães RC; CENPES/PETROBRAS, 21941-945 Rio de Janeiro, RJ, Brazil.
  • Guarnieri RA; CENPES/PETROBRAS, 21941-945 Rio de Janeiro, RJ, Brazil.
  • Fonseca TC; CENPES/PETROBRAS, 21941-945 Rio de Janeiro, RJ, Brazil.
  • Flores EM; Departamento de Química, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil. Electronic address: ericommf@gmail.com.
Anal Chim Acta ; 844: 8-14, 2014 Sep 24.
Article em En | MEDLINE | ID: mdl-25172810
A procedure for light and heavy crude oils digestion by microwave-induced combustion (MIC) is proposed for the first time for further rare earth elements (REE) determination by inductively coupled plasma mass spectrometry (ICP-MS) equipped with an ultrasonic nebulizer (USN). Samples of crude oil (API density of 10.8-23.5, up to 250 mg) were inserted in polycarbonate capsules and combusted using 20 bar of oxygen and 50 µL of 6 mol L(-1) ammonium nitrate as igniter. Nitric acid solutions (1-14.4 mol L(-1)) were evaluated for analyte absorption and a reflux step was applied after combustion (5 min of microwave irradiation at 1400 W) in order to achieve better analyte recoveries. Accuracy was evaluated using a spiked sample and also by comparison of results obtained by microwave-assisted digestion combined to ultraviolet radiation (MW-UV) and by neutron activation analysis (NAA). Using 3 mol L(-1) HNO3, quantitative recoveries (better than 97%) were obtained for all analytes. Blank values were always negligible. Agreement was higher than 96% for La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu and Y by comparison of results with those obtained by MW-UV and by NAA (only for La, Ce, Nd, Sm, and Yb). Residual carbon content in digests using MIC was always below 1%. As an advantage over conventional procedures for crude oil digestion, using MIC, it was possible to use diluted acid as absorbing solution, obtaining better limits of detection and avoiding interferences in REE determination by USN-ICP-MS.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chim Acta Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chim Acta Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda