Your browser doesn't support javascript.
loading
Parturient perineal distensibility tolerance assessed by EPI-NO: an observational study.
Nakamura, Mary Uchiyama; Sass, Nelson; Elito Júnior, Julio; Petricelli, Carla Dellabarba; Alexandre, Sandra Maria; Araujo Júnior, Edward; Zanetti, Miriam Raquel Diniz.
Afiliação
  • Nakamura MU; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Sass N; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Elito Júnior J; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Petricelli CD; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Alexandre SM; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Araujo Júnior E; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Zanetti MR; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Einstein (Sao Paulo) ; 12(1): 22-6, 2014.
Article em En | MEDLINE | ID: mdl-24728241
OBJECTIVE: To determine how parturient women tolerate the use of a perineal distensibility assessment technique using the EPI-NO device. METHODS: An observational study with a total of 227 full-term parturient women was performed. During the evaluation with EPI-NO, parturient patients were asked about their sensation of discomfort. The degree of discomfort was measured using the Visual Analogue Scale, with a score from zero to 10. The Mann-Whitney test was applied to assess perineal distensibility measured by EPI-NO and the degree of discomfort caused by the test according to parity. The relation between perineal distensibility and discomfort was analyzed by using the Spearman correlation test (r). RESULTS: The test with EPI-NO caused only slight discomfort (mean Visual Analogue Scale of 3.8), and primiparous women reported significantly greater discomfort (mean Visual Analogue Scale of 4.5) than did multiparous (mean Visual Analogue Scale=3.1), with p<0.001 women. A negative correlation was observed, in other words, the greater the perineal distensibility on the EPI-NO, the lower the pain reported by the patients (r=-0.424; p<0.001). CONCLUSION: The assessment of perineal distensibility with EPI-NO was well tolerated by the parturient women.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Períneo / Diafragma da Pelve / Complicações do Trabalho de Parto Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Einstein (Sao Paulo) Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Períneo / Diafragma da Pelve / Complicações do Trabalho de Parto Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Einstein (Sao Paulo) Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil